Showing all 25 results

  • 2 year warranty and 60 years of Dynisco industry experience
  • Accuracy better than ±0.5%
  • TiAlN diaphragm coating is standard
  • mV/V, 0-10VDC, or mA outputs available
  • Integral temperature sensor option
  • Available in configurations that fit most extruder applications
  • 1.5M, 3M, 5M, 7.5M & 10M psi pressure range capability
Datasheet

  • Integral relay switch for redundant safety and future compliance
  • 3rd-party agency analysis (exida™) and self-certified based on FMEDA analysis and internal audit.
  • Meets Performance Level ‘c’ as defined by the Machinery Directive (single sensor installed per Category 1).
  • Meets Performance Level ‘d’ as defined by the Machinery Directive (two sensors installed per Category 3).
  • Meets the following compliance directives, when properly installed and used:
    • Machinery Directive 2006/42/EC
    • NFPA 79 clauses A.9.2, A.9.4.1, A.9.4.3.2
    • EMC Directive 2004/108/EC
    • PED 97/23/EC
  • Available on popular mV/V (PT, MDA, DYN) and mA-HART SPX models
Datasheet

  • Adjustable zero and span, via side-mounted pots
  • Accuracy better than ±1.0%
  • DyMax® coated stainless steel wetted parts
  • 4-20 mA output
  • 0-500 to 0-30,000 psi
  • Internal 80% shunt calibration
Datasheet

  • Adjustable zero and span
  • Accuracy better than ±1.0%
  • DyMax® coated stainless steel wetted parts
  • 0 - 10 Vdc outputs
  • 0 - 500 to 0 - 10,000 psi
  • Internal 80% shunt calibrations
Datasheet

  • Economical and repeatable pressure meausurements
  • Superior abrasion resistance
  • Stability and repeatability
  • Variety of pressure ranges
  • Easy to calibrate
Datasheet

  • Accuracy better than ±0.25%
  • DyMax® coated stainless steel wetted parts
  • Proven sensor design
  • Excellent thermal stability and repeatability
  • 0 - 500 to 0 -30,000 psi
  • Internal 80% shunt calibration
Datasheet

  • Accuracy better than ±0.5%
  • DyMax® coated stainless steel wetted parts
  • Proven sensor design
  • 0 - 500 to 0 -30,000 psi
  • Internal 80% shunt calibration
Datasheet

  • Accuracy of better than ±0.25%
  • Choice of flanged or threaded configurations
  • 0 - 250 to 0 - 10,000 psi
  • Withstands processes up to 700°F
  • Internal 80% shunt calibration
  • Replacement for traditional “button - seal” units
Datasheet

  • Accuracy better than ±0.5%
  • DyMax® coated stainless steel wetted parts
  • Proven sensor design
  • 0 - 500 to 0 -30,000 psi
  • Internal 80% shunt calibration
Datasheet

  • Output: 3.33 mV/V +/- 2.0%
  • Input Voltage: 10 Vdc recommended, 12 Vdc maximum
  • Combined Error: +/- 0.25% FSO, (Including Linearity, Repeatability & Hysteresis) +/- 0.5% FSO for 500, 750, 1,000 psi ranges
  • Repeatability: +/- 0.1%FSO, +/- 0.2% FSO for 500, 750, 1,000 psi ranges
  • Configuration: Four-arm bonded foil Wheatstone bridge strain gage
  • Bridge Resistance: Input: 345 Ohms minimum, Output: 350 Ohms +/- 10%
  • Over Pressure: 2 X FSO or 35,000 psi whichever is less
  • Zero Balance: +/- 5% FSO
  • Internal Shunt Calibration (R-Cal): 80% FSO +/- 0.5%
  • Insulation Resistance: 1000 megohms @ 50 Vdc
Datasheet

  • 6 mm sensing element
  • Fits in space restricted areas
  • Exposed, bendable capillary
  • Ideal for injection molding nozzles
  • Internal 80% shunt calibration
  • Easy set - up
  • 0 - 5,000 to 0 - 10,000 psi
  • Choice of pressure ranges
  • Good stability and repeatability
  • Proven sensor design
  • Flexible stem
  • Easy to install, ideal for high local temperatures
  • Classic, standard design
  • Economically priced
Datasheet

  • 6 mm sensing element
  • Fits in space restricted areas, reduces mounting hole dead space
  • Internal 80% shunt calibration
  • Easy set - up
  • 0 - 5,000 to 0 - 10,000 psi
  • Choice of pressure ranges
  • Good stability and repeatability
  • Reliable pressure measurement
  • Flexible stem • Easy to install and ideal for high local temperatures
Datasheet

  • Accuracy better than ±1.0%
  • Inconel diaphragm
  • Superior temperature stability
  • Patented sensing element
  • 0 - 3,000 to 0 -30,000 psi
  • Internal 80% shunt calibration
Datasheet

  • Accuracy of better than ±1.0%
  • Reliable pressure measurement
  • Four user selectable pressure ranges in one model
  • Maximizes inventory flexibility
  • Externally selectable range via rotary switch
  • Maximum versatility for changing process conditions
  • 3.33 mV/V FSO for selected range
  • Standard low level output
  • Internal 80% shunt calibration
  • Easy set-up
  • All stainless steel wetted parts
  • Corrosion resistant
  • Proven sensor design
  • Good stability and repeatability
Datasheet

  • Accuracy of better than ±1.0% • Reliable pressure measurement
  • Four user selectable pressure ranges in one model
  • Maximizes inventory flexibility
  • Externally selectable range via rotary switch
  • Maximum versatility for changing process conditions
  • 3.33 mV/V FSO for selected range
  • Standard low level output
  • Internal 80% shunt calibration
  • Easy set-up
  • All stainless steel wetted parts
  • Corrosion resistant
  • Proven sensor design
  • Good stability and repeatability
  • Type J thermocouple
  • Simultaneously measure pressure/temperature in one location
Datasheet

Die Druckaufnehmer der Serie MDA liefern über ein geschlossenes, flüssigkeitsgefülltes Druckmittlersystem ein zum anstehenden Prozessdruck proportionales Ausgangssignal.

Datasheet

The pressure transducers of the MDA series supply an output signal that is proportional to the process pressure via a closed, liquid-filled diaphragm seal system.
Datasheet

  • Installation for media temperature up to 400 °C
  • l Flexible capillary between rigid stem and housing
  • l Liquid-filled transmission system
  • l Electrical built-in calibration
 
Datasheet

  • Accuracy better than +/- 0.5%
  • Dymax® coated stainless steel wetted parts
  • Proven sensor design
  • 0 - 500 to 0 -30,000 psi
  • Internal 80% shunt calibration
  • Reliable, repeatable pressure measurements
  • Superior abrasion resistance
  • Good stability and repeatability
  • Wide variety of pressure ranges
  • Easy to calibrate with local indicator
 
Datasheet

  • Installation for media temperature up to 400 °C
  • l Flexible capillary between rigid stem and housing
  • l Liquid-filled transmission system
  • l Electrical built-in calibration
 
Datasheet

The pressure transmitters of the TDA series are based on the proven MDA series. They supply an output signal that is proportional to the process pressure via a closed, liquid-filled diaphragm seal system. Thanks to the integrated thermocouple, it is possible to measure the temperature directly on the medium at the same time.

Datasheet

  • Installation for media temperature up to 400 °C
  • l Integral thermocouple for simultaneous temperature measurement at the media
  • l Flexible capillary between rigid stem and housing
  • l Liquid-filled transmission system
  • l Electrical built-in calibration
 
Datasheet

  • Better than ±0.5% accuracy
  • 4 to 20 mA, 0 to 5 Vdc, 1 to 6 Vdc, 0 to10 Vdc, 1 to 11 Vdc outputs
  • Stainless steel, Armoloy coated
  • 0 - 500 to 0 - 30,000 psi
  • Internal 80% shunt calibration
  • Adjustable zero and span
  • Integral thermocouple
  • Reliable pressure measurement
  • Direct input to supervisory control systems
  • Minimizes thread galling, abrasion resistant
  • Choice of pressure ranges
  • Easy set-up
  • Adapt transmitter to process conditions
  • Simultaneously measure pressure/temperature in one location
 
Datasheet

  • Better than ±0.5% accuracy
  • 4 to 20 mA, 0 to 5 Vdc, 1 to 6 Vdc, 0 to10 Vdc, 1 to 11 Vdc outputs
  • Stainless steel, Armoloy coated
  • 0 - 500 to 0 - 30,000 psi
  • Internal 80% shunt calibration
  • Adjustable zero and span
  • Integral thermocouple
  • Reliable pressure measurement
  • Direct input to supervisory control systems
  • Minimizes thread galling, abrasion resistant
  • Choice of pressure ranges
  • Easy set-up
  • Adapt transmitter to process conditions
  • Simultaneously measure pressure/temperature in one location
 
Datasheet

  • Better than ±0.5% accuracy
  • 4 to 20 mA, 0 to 5 Vdc, 1 to 6 Vdc, 0 to10 Vdc, 1 to 11 Vdc outputs
  • Stainless steel, Armoloy coated
  • 0 - 500 to 0 - 30,000 psi
  • Internal 80% shunt calibration
  • Adjustable zero and span
  • Integral thermocouple
  • Reliable pressure measurement
  • Direct input to supervisory control systems
  • Minimizes thread galling, abrasion resistant
  • Choice of pressure ranges
  • Easy set-up
  • Adapt transmitter to process conditions
  • Simultaneously measure pressure/temperature in one location
 
Datasheet

Diese Website benutzt Cookies. Wenn du die Website weiter nutzt, gehen wir von deinem Einverständnis aus.