Showing all 12 results

  • Zero point correction in front
  • Completely from stainless steel
  • With liquid-filled case for applications with high dynamic pressure loads and vibrations (model 633.50)
  • Low scale ranges from 0 ... 2.5 mbar to 0 ... 600 mbar or 0 ... 1 inH2O to 0 ... 240 inH2O
Datasheet
User Manual
User Manual

  • High overload safety up to 50 x full scale value
  • Scale ranges from 0 … 2.5 mbar
  • Measuring chamber protected against unauthorised intervention
  • Low measuring error and influence on function from medium pollution
Datasheet
User Manual
User Manual

  • Zero point setting in front
  • Special connection location on request
  • Low scale ranges from 0 ... 25 mbar
Datasheet
User Manual

  • Zero point correction in front
  • Case from stainless steel
  • Robust design and ingress protection IP54
  • Low scale ranges from 0 ... 6 mbar to 0 ... 600 mbar or 0 ... 2.4 inH2O to 0 ... 240 inH2O
Datasheet
User Manual

  • Safety version with solid baffle wall designed in compliance with the requirements and test conditions of ASME B 40.100
  • Low scale ranges from 0 ... 25 mbar to 0 ... 600 mbar
  • Nominal size 4 ½" (115 mm)
  • Robust, glass-fibre reinforced case from POCAN®
Datasheet
User Manual

  • Compact design and ingress protection IP53
  • Case from plastic
  • Special connection location on request
  • Low scale ranges from 0 ... 60 mbar
  • Maximum scale range 0 ... 1,000 mbar
Datasheet
User Manual

  • High overload safety up to 50 x full scale value
  • High reliability and long service life
  • Up to 4 switch contacts per instrument
  • Instruments with inductive contacts for use in hazardous areas
  • Instruments with switch contact for PLC applications
Datasheet
User Manual
User Manual

  • No configuration necessary due to "plug-and-play"
  • High overload safety up to 50 x full scale value
  • Easy-to-read analogue display with nominal sizes 100 and 160
  • Low measuring error and influence on function from medium pollution
  • Measuring chamber protected against unauthorised intervention
Datasheet
User Manual

High reliability and long service life Overload protection ,up to x 10 Zero adjustment Copper alloy measuring system

Datasheet

Nominal size NS 100 and 160, accuracy class 1.6, according to DIN EN 837-3
Datasheet

Nominal size NS 100 and 160, accuracy class 1.6, according to DIN EN 837-3
Datasheet

Diese Website benutzt Cookies. Wenn du die Website weiter nutzt, gehen wir von deinem Einverständnis aus.