Showing all 34 results

Digital 2-wire transmitter for thermocouple with wireless communication

  • Type: Digital
  • Input: TC
  • Output: 4-20 mA
  • Isolation: Unisolated
  • Measuring channels: 1 channel
Datasheet

Digital 2-wire transmitter for thermocouple with wireless communication

  • Type: Digital
  • Input: TC
  • Output: 4-20 mA
  • Isolation: Unisolated
  • Measuring channels: 1 channel
Datasheet

Digital 2-wire transmitter for Pt100 and Pt1000 with wireless communication

  • Type: Digital
  • Input: RTD
  • Output: 4-20 mA
  • Isolation: Unisolated
  • Measuring channels: 1 channel
Datasheet

Digital 2-wire transmitter for Pt100 and Pt1000 with wireless communication

  • Type: Digital
  • Input: RTD
  • Output: 4-20 mA
  • Isolation: Unisolated
  • Measuring channels: 1 channel
Datasheet

Analog Adjustable 3-wire Transmitters
  • Type: Analog
  • Input: RTD
  • Utgång: 0-10 V
  • Isolation: Unisolated
  • Measuring channels: 1 channel
Datasheet

Type Head mounted
Input RTD
Input RTD Pt100
Type of transmitter Digital
Output 4-20 mA
Isolation Unisolated
Measuring channels 1 channel
Sensor connection 3-wire connection
Power Supply Standard version: 6 to 32 VDC Ex version: 8 to 30 VDC
Typical accuracy Max. ±0.1K or ±0,1 % of span
Approvals (IPAQ-C202X) ATEX: II 1G Ex ia IIC T6…T4 Ga IECEx: Ex ia IIC T6…T4 Ga
Datasheet

Universal 2-wire transmitter with wireless communication
  • Type: Digital
  • Input: RTD, thermocouple, Universal
  • Output: 4-20 mA
  • Isolation: Isolated
  • Measuring channels: 1 channel
Datasheet

Basic Programmable 2-wire Transmitter

  • Type: Digital
  • Input: RTD thermocouple
  • Output: 4-20 mA
  • Isolation: Unisolated
  • Measuring channels: 1 channel
Datasheet

Universal HART-compatible 2-wire transmitter with NFC

  • Type: Digital
  • Input: RTD, thermocouple, Universal
  • Output: 4-20 mA, HART-protocol
  • Isolation: Isolated
  • Measuring channels: 1 channel
Datasheet

HART Compatible Universal Dual-input 2-wire Transmitters

  • Type: Digital
  • Input: RTD, thermocouple, Universal
  • Output: 4-20 mA, HART®
  • Isolation: Isolated
  • Measuring channels: 2 channels
Datasheet

Analog Adjustable 2-wire Transmitters

  • Type: Analog
  • Input: RTD, thermocouple
  • Output: 4-20 mA
  • Isolation: Unisolated
  • Measuring channels: 1 channel
Datasheet

Programmable 2-wire Transmitter dedicated for Pt100 sensors
  • Type: Digital
  • Input: RTD
  • Output: 4-20 mA
  • Isolation: Unisolated
  • Measuring channels: 1 channel
Datasheet

Basic Programmable 2-wire Transmitter

  • Type: Digital
  • Input: RTD, thermocouple
  • Output: 4-20 mA
  • Isolation: Unisolated
  • Measuring channels: 1 channel
Datasheet

Universal Programmable 2-wire Transmitters
  • Type: Digital
  • Input: RTD, thermocouple, Universal
  • Output: 4-20 mA
  • Isolation: Isolated
  • Measuring channels: 1 channel
Datasheet

HART Compatible Universal Dual-input 2-wire Transmitters
  • Type: Digital
  • Input: RTD, thermocouple, Universal
  • Output: 4-20 mA, HART®
  • Isolation: Isolated
  • Measuring channels: 2 channels
Datasheet

Analog Adjustable 3-wire Transmitters
  • Type: Analog
  • Input: RTD
  • Output: 0-10 V
  • Isolation: Unisolated
  • Measuring channels: 1 channel
Datasheet

Universeller, programmierbarer Präzisions- Zweidraht-Transmitter
  • Typ: Digital
  • Eingang: RTD, Thermoelement, Universal
  • Ausgang: 4-20 mA
  • Galvanische Trennung: Ja
  • Messkanäle: 1 Kanal
Datasheet

Universal High-Isolation 4-wire Transmitter
  • Type: Digital
  • Input: RTD, thermocouple, Universal
  • Output: 4-20 mA, 0-10 V
  • Isolation: Isolated
  • Measuring channels: 1 channel
Datasheet

Universal HART-compatible 2-wire transmitter with NFC
  • Type: Digital
  • Input: RTD, thermocouple, Universal
  • Output: 4-20 mA, HART-protocol
  • Isolation: Isolated
  • Measuring channels: 1 channel
Datasheet

  • For the connection of Pt100 and Pt1000 sensors in a 2-, 3- or 4-wire connection
  • For the connection of reed chains in a potentiometer circuit
  • Parameterisation with the WIKAsoft-TT configuration software and electrical connection via quick connector magWIK
  • Connection terminals also accessible from the outside
  • Accuracy < 0.2 K (< 0,36 °F) / 0.1 %
Datasheet
User Manual

Digital transmitter to be built into own equipment

  • Type: Digital
  • Input: RTD
  • Output: 4-20 mA
  • Isolation: Unisolated
  • Measuring channels: 1 channel

  • Easy configuration via DIP switch or via INOR-Set
  • Switchable service functions for easy commissioning
  • 3-port isolation Protection against measurement errors due to earthing problems and interference voltage carry-over
  • Extremely slim design 6.2 mm narrow bayed housing for simple and space-saving top-hat rail mounting
  • Optional in-rail bus mounting rail connector allows fast and cost-effective installation
  • Safe isolation according to EN 61140 Protection of maintenance personnel and downstream equipment from impermissibly high voltage
Datasheet
Flyer
User Manual

Digital transmitter to be built into own equipment

  • Type: Digital
  • Input: RTD
  • Output: 4-20 mA
  • Isolation: Unisolated
  • Measuring channels: 1 channel

Digital transmitter to be built into own equipment

  • Type: Digital
  • Input: RTD
  • Output: 4-20 mA
  • Isolation: Unisolated
  • Measuring channels: 1 channel

  • For the connection of all standard thermocouples
  • High accuracy
  • Parameterisation with the WIKAsoft-TT configuration software and electrical connection via quick connector magWIK
  • Connection terminals also accessible from the outside
  • EMC stability in compliance with the latest standard (EN 61326-2-3:2013)



Datasheet
User Manual

  • TÜV certified SIL version for protection systems developed per IEC 61508 (option)
  • Operation in safety applications to SIL 2 (single instrument) and SIL 3 (redundant configuration)
  • Configurable with almost all soft- and hardware tools
  • Universal for the connection of 1 or 2 sensors
    - Resistance thermometer, resistance sensor
    - Thermocouple, mV sensor
    - Potentiometer
  • Signalling in accordance with NAMUR NE43, sensorbreak detection in accordance with NE89, EMC in accordance with NE21

Datasheet
User Manual
User Manual

  • Model OTMT84: PROFIBUS® PA profile 3.02
  • Model OTMT85: FOUNDATION™ Fieldbus H1
  • Explosion-protected version Ex ia (intrinsically safe/FISCO) and Ex ec available
Datasheet
User Manual
User Manual

  • Versions for Pt100 / Pt1000 or thermocouples
  • Output 0 ... 10 V, 3-wire (T91.10) or 4 ... 20 mA, 2-wire (T91.20)
  • Error signalling in the event of sensor break
  • High accuracy
  • Compact and value for money
Datasheet
User Manual

  • Measuring ranges from -50 ... +200 °C [-58 ... +392 °F]
  • Electrical connection via plug connection
  • Output signal 4 … 20 mA or 0 … 10 V
  • Factory configured
  • Measuring insert exchangeable
Datasheet
User Manual

Analog Adjustable 2-wire Transmitters
  • Type: Analog
  • Input: RTD, thermocouple
  • Output: 4-20 mA
  • Isolation: Unisolated
  • Measuring channels: 1 channel
Not available anymore.



Datasheet

High-precision Universal Programmable 2-wire Transmitter
  • Type: Digital
  • Input: RTD, thermocouple, Universal
  • Output: 4-20 mA
  • Isolation: Isolated
  • Measuring channels: 1 channel
Datasheet

  • Connection heads
  • Thermo junction
  • Connector
  • Fixing materials
  • Extension protecting tubes
  • Calibration block
  • Miniature fixed-point cell
  • Reference junction
  • Transmitter
  • Digital thermometer
Product catalog

Diese Website benutzt Cookies. Wenn du die Website weiter nutzt, gehen wir von deinem Einverständnis aus.