Pressure Measurement Temperature measurement Vibration analysis Force and strain measurement Flow Measurement Speed and position measurement Environmental audits Quality control and material testing

 

In the aerospace industry, measurement and testing technology plays a crucial role in ensuring the safety, reliability, and performance of aircraft and spacecraft. Due to the extreme conditions that aerospace components are subjected to, including high speeds, pressure differences, temperature fluctuations, and mechanical stresses, measurement and testing systems must meet the highest standards.

 

Pressure measurement is essential for monitoring cabin pressure conditions, hydraulic systems, fuel systems, and environmental conditions. Specially designed pressure sensors and transmitters must provide precise measurements under the harsh conditions of high-altitude flights and space.

  • Interchangeable reference sensors that can be changed via the front
  • Large colour touchscreen with all necessary information
  • Control stability 0.001 % of span
  • Accuracy up to 0.009 % IS-50 (IntelliScale)
Datasheet

  • High Precision, ±0.01% FS over compensated temperature range
  • High Stability, ±100 ppm FS/year
  • Wide temperature range, up to -40°C to +125°C (-40° to 257°F)
  • Media isolated construction, suitable for use in harsh environments
  • Multiple output configurations, RS-232, RS-485, USB 2.0, CAN Bus, frequency and diode (TTL)
  • Wide selection of pressure and electrical connections to suit specific requirements
Datasheet

  • High Precision, ±0.01% FS over compensated temperature range
  • High Stability, ±50 ppm FS/year (typical)
  • Wide temperature range, up to -55 to +125°C (-67 to 257°F)
  • Multiple Output configurations, RS232, RS485, USB 2.0, CAN Bus, Frequency & Diode (TTL)
  • Wide selection of pressure & electrical connections to suit specific requirements
  • Low acceleration effects
Datasheet
User Manual

Specially designed for the calibration and testing of tire pressure manometern

Datasheet

The DPI610E not only delivers highly accurate measurements – it does so for a wide variety of pressure ranges (350mbar / 5 psi / 33 kPa to 1000bar /15000 psi / 100 MPa ). That means one device can cover all your calibration needs – reducing both cost of ownership and maintenance.



Datasheet
User Manual
Quick Start

 

Temperature Measurement is of great importance for monitoring critical systems such as engines, avionics, and environmental control systems. Thermocouples, Resistance Temperature Detectors (RTDs), and Infrared Sensors are used to monitor temperature ranges from extremely cold to extremely hot, ensuring optimal performance and safety.

  • Extremely accurate in very low temperature ranges, i.e. cold storage rooms
  • Optional connectable temperature sensor and wireless sensor for different applications in the field
  • Audible alarm, user-defined thresholds
  • HACCP compliant, certified according to EN 13485 for use in the food sector
Datasheet
User Manual

  • Thermal resolution: 384 x 288 (110,592 pixels)
  • NETD: < 30 mK (@ 25°C, F#=1.0)
  • Start up time: 5 seconds (with IR image), 10 seconds (with OSD)
  • Support object details enhancement
  • Temperature measurement range: -20°C to 1200°C (-4°F to 2192°F)
  • Measurement presets: Center spot, Hot spot, Cold spot
  • 60 Hz image frequency
  • 4.3" LCD screen display
Datasheet
User Manual

  • High accuracy of 0.03 K with Pt100
  • One- and two-channel versions
  • Connection possibilities for various probe types
  • Intrinsically safe version Ex ib IIB T4 Gb


Datasheet
User Manual
User Manual

  • Extended temperature range for reliable measurements up to 2,732 °F
  • IR measurements from a safe distance; precise measuring of moving objects
  • Memory of up to 200 readings; easy analysis with free to download software
  • 4-point laser and 50:1 optics for precise measurements over greater distances
Datasheet
User Manual
User Manual
User Manual

 

Vibration Analysis helps to verify the structural integrity of aerospace vehicles. Vibration sensors and analyzers are used to detect potential problems early on, ranging from loose components to structural damage.

  • Sensor principle Capacitive acceleration sensor
  • Frequency range 1 ... 100 Hz
  • Measuring range ±50 G
  • Output signal Frequency (square wave signal)
  • Nonlinearity < ±2%
  • Measuring accuracy < ±2%
  • Electrical connector M16 x 0.75, 5-pin
  • Mechanical connection Magnetic base
  • Body material Plastic; resistant to fuels, oils, salts, and specific chemicals
  • Ambient temperature -20 ... 85 °C
  • IP degree of protection IP66 (sensor element)
  • Weight 547 g
Datasheet

  • Measuring range freely selectable between -45 ... +45°
  • Relative linearity error < 0.1 % of FS over the entire measuring range
  • Good damping behaviour, no gravitational acceleration error
  • Resistant to seawater, IP67
  • 2 axes freely selectable
Datasheet

 

Force and strain measurement are used to assess the stress and strain of materials and components. Force sensors, strain gauges, and load cells contribute to ensuring the structural integrity and performance of aerospace structures.

  • Measuring ranges 10 kN, 20 kN
  • Relative linearity error 0.2 % Fnom
  • Low overall weight of approx. 6 kg
  • Maximum/Minimum value memory
  • Electrode diameter 14 … 20 mm
Datasheet

  • Measuring ranges 0 ... 6 t up to 0 … 25 t (others possible)
  • Relative linearity error < 0.5 % Fnom
  • Type tested in accordance with OIML R60 (certificate R60/2000-A-NL-18.05) with D175
  • Optimal for retrofitting with simple integration into the crane network through CANopen® and CAN SAE J1939 technologies
  • High overload capacity, long service life of the measuring spring, large shock and vibration resistance
Datasheet

  • Measuring ranges 40 ... 3,500 kg
  • Simple calibration of friction clutches without weights
  • Single sensor concept for entire load range
  • Maximum- / minimum value memory
  • Relative linearity error 0.5 % Fnom
Datasheet

  • Measuring ranges 0 ... 1 t to 0 ... 30 t
  • Relative linearity error up to ≤ ±1.0 % Fnom
  • Wire rope diameter 8 ... 44 mm, suitable for retrofitting
  • Material: Stainless steel, IP67
  • Optional: Redundant output signal, ATEX version
Datasheet
User Manual

  • Measuring ranges strains from 0 ... 200 με up to max. 0 ... 1,000 με
  • Good long-term stability, high shock and vibration resistance, good reproducibility
  • As retrofitting, easy to install
  • For use in extreme outdoor applications (IP67)
  • Relative linearity error < 2 % Fnom
Datasheet
User Manual

  • Strain of 0 … 200 με to max. 0 … 1,000 με
  • Can be retrofitted, easy installation with M6-screws
  • Total error < 1 % Fnom
  • Electrical connection as cable, with plug-in radio module, display or junction box.
Datasheet

  • Measuring ranges 0 ... 6 t up to 0 … 25 t (others possible)
  • Relative linearity error 2 % Fnom
  • Optimal for retrofitting with simple integration into the crane network through CANopen® and CAN SAE J1939 technologies
  • High overload capacity, long service life of the measuring spring, large shock and vibration resistance
  • Exceptionally space-saving, ideal for retrofitting onto the spreader
Datasheet

  • Measuring ranges 0 … 1 t up to 0 ...4 0 t
  • Integrated amplifier, output 4 … 20 mA, 2-wire
  • Simple mounting (without opening rope), suitable for retrofits
  • Material alloyed steel
  • Protection class IP66
Datasheet
User Manual

  • 5-digit digital display, easy to read up to 50 m
  • High accuracy: 0.02 % of reading +3 μV
  • Extensive functions easy to set on the instrument or via PC
  • Plug-in expansion cards, analogue output, 2 or 4 limit values, serial interface
  • Ingress protection IP65
Datasheet

  • 6-digit liquid crystal display (LCD) with backlighting
  • Extensive functions easy to set on the instrument or via PC
  • International approval for applications requiring verified measurements OIML, NTEP
  • AC, DC (DC 7 ... 24 V) operating on (rechargeable) battery power (DC 4.8 ... 24 V) – ideal for a number of mobile applications
  • High ingress protection, IP65
Datasheet

  • 5-digit digital display, easy to read up to 50 m
  • High accuracy: 0.03 % of reading +2 μA or +2 mV
  • Extensive functions easy to set on the instrument or via PC
  • Plug-in expansion cards, analogue output, 2 or 4 limit values, serial interface
  • Ingress protection IP65
Datasheet

  • Certified safety electronics, certified in accordance with DIN EN ISO 13849-1, PLe
  • Certified system solution incl. force measurement, certified in accordance with DIN EN 13849-1 Cat. 3, PLd
  • 16 x safe inputs (8 x 4 ... 20 mA analogue inputs, 8 x digital inputs), 2 x safe relay outputs and 6 x safe solid-state outputs (positive switching)
  • Additional module with ProfiBus®, ProfiNet®, EtherCat® and CANopen®
  • Complex functionality, easy to configure via PC
Datasheet
User Manual

  • Reliable electrical connection
  • Pre-assembled
  • Shielded for high electromagnetic immunity
  • Ready for immediate use
  • Optional: with knurled nut made from stainless steel
Datasheet

  • 24 input/output channels (of which 8 are analogue inputs, 2 CAN bus interfaces)
  • Complex functionality, easy to configure via PC
  • Including application and AMP plug connection
  • High EMC and shock/vibration resistance
  • Robust metal case, ingress protection IP67
Datenblatt

  • Good linearity
  • Voltage and current output
  • Compact design
  • Optional, continuous adjustment of zero point and full scale
  • Optional with adapter board for DIN-rail mounting
Datasheet

  • Analogue input 0/4 ... 20 mA 2- and 3-wire
  • Galvanic isolation, line break (LB) and short-circuit (SC) monitoring
  • Easy setting of extensive functions on the instrument or via PC software
  • Two potential-free relay contacts (change-over) with status LED and a freely-programmable analogue output (0 ... 20 mA)
Datasheet
User Manual

  • High accuracy
  • Input signal: strain gauge resistance thermometry bridge; output signal 0/4 ... 20 mA or DC 0 ... 10 V
  • Cable length between amplifier and read-out unit: up to 100 m are possible
  • Compact design
  • Ingress protection IP67
Datasheet

  • High accuracy
  • Input signal: strain gauge measuring bridge; Output signal: 0/4 … 20 mA or DC 0 … 10 V
  • Cable length between amplifier and read-out unit: up to 100 m are possible
  • Compact design
  • Ingress protection IP67
Datasheet
User Manual

  • Limit switch for mV/V signals
  • 3 relay outputs
  • Adjustable control for switching thresholds
  • Simple operation and setting
  • Case for DIN-rail mounting
Datasheet

  • 4-channel
  • Rugged stainless steel case
  • Cable connection via clamps
  • IP67
Datasheet

  • Dual mV/V display
  • 2x digital input and 4x digital output
  • Integrated multiple signal outputs available
  • Serial interface, RS-232 or RS-485
  • Ingress protection IP65
Datasheet

  • Measuring ranges 0 ... 550 N to 0 ... 310 kN [0 ... 123,645 lbf to 0 ... 69,691 lbf]
  • Relative linearity error: ±1.0 ... 1.6 % Fnom with analogue pressure gauge, ≤ ±0.5 % Fnom with digital pressure gauge or pressure sensor
  • Piston stroke ≤ 0.5 mm [≤ 0.02 in]
  • Operates without supply voltage
  • 5-year leak-tightness warranty

  • Measuring ranges 0 ... 3 kN to 0 ... 450 kN
  • Relative linearity error 2 % Fnom
  • Material: Stainless steel
  • Ingress protection IP65
Datasheet

  • Measuring ranges 0 ... 15 kN to 0 ... 1,500 kN
  • Compact design, easy installation
  • Ingress protection IP65
  • Relative linearity error 1 % Fnom
Datasheet

  • Measuring ranges 0 ... 2 kN up to 0 ... 100 kN
  • For compression force measurements
  • Flat dimensions
  • Stainless steel measuring body
  • Protection class IP65
Datasheet

  • Measuring ranges 0 ... 800 kN to 0 ... 6,000 kN [179,847 lbf to 1,348,854 lbf]
  • Relative linearity error ±1.0 % Fnom with analogue pressure gauge, ±0.5 % Fnom with digital pressure gauge or pressure sensor
  • Piston stroke ≤ 0.5 mm [≤ 0.02 in]
  • Operation without supply voltage with analogue displays
  • Case and piston made of galvanised steel
Datasheet
User Manual

  • Measuring ranges 0 ... 400 kN to 0 ... 3,200 kN [0 ... 89,924 lbf to 0 ... 719,389 lbf]
  • Relative linearity error ±1.0 % Fnom with analogue pressure gauge, ±0.5 % Fnom with digital pressure gauge or pressure sensor
  • Piston stroke ≤ 0.5 mm [≤ 0.02 in]
  • Operates without supply voltage
  • Case and piston made of galvanised steel
Datasheet
User Manual

  • Measuring ranges 0 ... 25 kN to 0 ... 1,500 kN [5,620 lbf to 337,213 lbf]
  • Relative linearity error ±1.0 ... 1.6 % Fnom with analogue pressure gauge, ±0.5 % Fnom with digital pressure gauge or pressure sensor
  • Piston stroke ≤ 0.8 mm [≤ 0.03 in]
  • Operates without supply voltage
  • 5-year leak-tightness warranty
Datasheet

  • Measuring ranges 0 ... 150 kN to 0 ... 1,500 kN [0 ... 33,721 lbf to 0 ... 337,213 lbf]
  • Relative linearity error ±1.0 % Fnom with analogue pressure gauge, ±0.5 % Fnom with digital pressure gauge or pressure sensor
  • Piston stroke ≤ 0.5 mm [≤ 0.02 in]
  • Operates without supply voltage
  • Case and piston made of galvanised steel
Datasheet
User Manual

  • Measuring ranges 0 ... 80 kN to 0 ... 700 kN [0 ... 17,985 lbf to 0 ... 157,366 lbf]
  • Relative linearity error ±1.0 % Fnom with analogue pressure gauge, ±0.5 % Fnom with digital pressure gauge or pressure sensor
  • Piston stroke ≤ 0.5 mm [≤ 0.02 in]
  • Operates without supply voltage
  • Case and piston made of galvanised steel
Datasheet
User Manual

  • Measuring ranges 0 ... 320 N to 0 ... 120 kN [0 ... 72 lbf bis 0 ... 26,977 lbf]
  • Relative linearity error ±1.0 ... ±1.6 % Fnom with analogue pressure gauge, ±0.5 % Fnom with digital pressure gauge or pressure sensor
  • Piston stroke ≤ 0.5 mm [≤ 0.02 in]
  • Operates without supply voltage
  • 5-year leak-tightness warranty
Datasheet

  • Fine-grained structural steel with high-quality surface protection or in corrosion-resistant stainless steel version
  • High long-term stability, high shock and vibration resistance
  • For dynamic and static measurements
  • Excellent reproducibility
Datasheet
User Manual

  • Measuring ranges 0 ... 5 kN up to 0 ... 10,000 kN
  • Corrosion-resistant stainless steel design
  • Existing non-measuring bolts are simply replaced by the measuring axes
  • For overload protection in cranes and hoists
  • Good reproducibility, simple installation
Datasheet

  • Measuring ranges from 0 ... 10 kN [from 0 ... 2,248 lbf]
  • Stainless steel version (corrosion-resistant)
  • Integrated amplifier
  • High long-term stability, high shock and vibration resistance
  • Good reproducibility, simple installation
Datasheet
User Manual

  • Measuring ranges 0 ... 5 kN to 0 ... 200 kN [0 ... 1,124 lbf to 0... 44,962 lbf]
  • Stainless steel version (corrosion-resistant)
  • Integrated amplifier
  • High long-term stability, high shock and vibration resistance
  • Good reproducibility, simple installation
Datasheet
User Manual

  • Measuring ranges 0 ... 2 kg to 0 ... 30 kg [0 ... 4 lbs to 0 ... 66 lbs]
  • Load cell made from aluminium
  • High accuracy, react quickly, low settling time
  • Insensitive to lateral and corner load
  • Simple design, easy installation
Datasheet

  • Measuring ranges 0 ... 3 kg to 0 ... 40 kg [0 ... 7 lbs to 0 ... 88 lbs]
  • Load cell made from aluminium
  • High accuracy, react quickly, low settling time
  • Insensitive to lateral and corner load
  • Simple design, easy installation
Datasheet

  • Measuring ranges 0 ... 8 kg to 0 ... 300 kg [0 ... 18 lbs to 0 ... 661 lbs]
  • Load cell made from aluminium
  • High accuracy, react quickly, low settling time
  • Insensitive to lateral and corner load
  • Simple design, easy installation
Datasheet

  • Measuring ranges 0 ... 50 kg to 0 ... 635 kg [0 ... 110 lbs and 0 ... 1,400 lbs]
  • Load cell made from aluminium
  • High accuracy, react quickly, low settling time
  • Insensitive to lateral and corner load
  • Simple design, easy installation
Datasheet

  • Measuring ranges 0 ... 1 kg to 0 ... 200 kg [0 ... 2.2 lbs to 0 ... 441 lbs]
  • Load cell made from aluminium
  • High accuracy (6-wire connection), react quickly, low settling time
  • Insensitive to lateral and corner load
  • Simple design, easy installation
Datasheet

  • Measuring ranges 0 … 20 kg up to 0 ... 500 kg
  • Made of aluminum
  • High accuracy
  • Insensitive to side and corner loads
  • Simple structure, easy to install
Datasheet
User Manual

  • High overload protection up to 400 %
  • 0.1 % FS Accuracy
  • Meets the highest EMC requirements
  • Measuring ranges 0 ... 27.22 kg to 0 ... 136.08 kg [0 ... 60 lbs to 0 ... 300 lbs]
  • High ingress protection, IP65, for outdoor use and processes with high condensation
Datasheet
User Manual

  • Measurement ranges 0 ... 3 kg up to 0 ... 250 kg
  • Made of aluminum alloy
  • High accuracy
  • High side load tolerance
  • Simple structure, easy to install
Datasheet
User Manual

  • Measuring ranges 0 … 0.3 kg up to 0 ... 10 kg
  • Made of aluminum alloy
  • High accuracy
  • Insensitive to side and corner loads
  • Simple structure, easy to install
Datasheet
User Manual

  • Measuring ranges 0 … 5 kg up to 0 ... 500 kg
  • Completely welded bellows
  • Protection class IP68
Datasheet

  • Measuring ranges 0 … 500 kg up to 0 ... 10.000 kg
  • Steel/stainless steel
  • High long-term stability
  • High side load tolerance
Datasheet

  • Measuring ranges 0 ... 2 kN up to 0 ... 100 kN
  • Corrosion-resistant stainless steel design
  • Integrated amplifier
  • High long-term stability, high shock and vibration resistance
  • Good reproducibility, simple installation
Datasheet
User Manual

  • Measuring ranges 0 ... 20 kg to 0 ... 500 kg
  • 3,000 intervals per OIML R60 Class C
  • Stainless steel, hermetically sealed and welded bellows
  • Ingress protection: IP68 and IP69K
Datasheet
User Manual

  • Measuring ranges 0 ... 500 to 0 ... 2,000 kg
  • 3,000 intervals per OIML R60 Class C
  • Stainless steel, hermetically sealed and welded, Ingress protection: IP68 and IP69K
  • High long-term stability
  • High side load tolerance
Datasheet
User Manual

  • Measuring ranges 0 ... 10 kN to 0 ... 45 kN [0 ... 2,248 lbf to 0 ... 10,116 lbf]
  • Corrosion-resistant stainless steel design
  • Integrated amplifier
  • High long-term stability, high shock and vibration resistance
  • Good reproducibility, simple installation
Datasheet
User Manual

  • Measuring ranges 0 ... 10 N up to 0 ... 5,000 N
  • Standard calibration: tension / compression (positive in tension)
  • Ease of assembly
  • Small geometries
  • Stainless steel version
Datasheet
User Manual

  • Measuring ranges 0 ... 5 kN up to 0 ... 500 kN
  • Ultra compact design
  • Simple installation, low installation height
  • Protection IP66
Datasheet
User Manual

  • Measuring ranges 0 ... 50 N up to 0 ... 1,000 N
  • Ultra compact design
  • Corrosion-resistant stainless steel design
  • Protection IP65
Datasheet
User Manual

  • Measuring ranges 0 … 5 N up to 0 ... 2,000 N
  • Overload protection
  • Ultracompact version
  • Material: Stainless steel
Datasheet
User Manual

  • Measuring ranges 0 ... 0,5 kN up to 0 ... 50 kN
  • Corrosion-resistant stainless steel or steel design
  • Protection IP65 (< 5 kN), IP67 (≥ 5 kN)
Datasheet
User Manual

  • Measuring ranges 0 ... 1 kN to 0 ... 200 kN [0 ... 225 lbf to 0 ... 44,962 lbf]
  • Corrosion-resistant stainless steel design
  • Integrated amplifier
  • High long-term stability, high shock and vibration resistance
  • Good reproducibility, simple installation
Datasheet
User Manual

  • Measuring ranges 0 ... 1 kN to 0 ... 500 kN [0 ... 224.8 lbf to 0 ... 112,404 lbf]
  • Stainless steel version (corrosion-resistant)
  • Integrated amplifier
  • High long-term stability, high shock and vibration resistance
  • Good reproducibility, easy installation
Datasheet
User Manual

  • Measuring ranges 0 ... 0.22 kN up to 0 ... 890 kN (0 ... 50 lbs up to 0 ... 200,000 lbs)
  • Robust design
  • Material stainless steel
  • Protection class IP66
  • Relative linearity error 0.1 % Fnom
Datasheet

  • Measuring ranges 0 ... 10 kN up to 0 ... 3,300 kN
  • Robust design
  • Material stainless steel
  • Protection class IP66
  • Relative linearity error 0.15 % Fnom
Datasheet
User Manual

  • Measuring ranges 0 ... 22 N up to 0 ... 2.200 kN (0 ... 5 Ibs up to 0 ... 500 klbs)
  • Simple installation, low installation height
  • High long-term stability, dynamic fatigue strength for load alternations
  • Protection class IP66
  • Relative linearity error 0.1 % Fnom
Datasheet

  • Measuring ranges 0 … 10 N up to 0 ... 50 kN
  • Standard calibration: tension / compression (positive in tension)
  • Ease of assembly
  • Small geometries
  • Stainless steel version
Datasheet
User Manual

  • Measuring ranges 0 ... 10 t to 0 ... 50 t
  • Relative linearity error 0.03 % Fnom
  • Material: Stainless steel version, IP67
  • Self-centring rocker pins with dual spherical force introduction
  • Adapter plates available
Datasheet

  • Measuring ranges 0 ... 7.5 t to 0 ... 300 t
  • For compression forces
  • Ingress protection IP68, hermetically sealed
  • Relative linearity error from 0.0166 % Fnom
Datasheet

  • Measuring range from 1 t
  • Relative linearity error ±0.15 % Fnom
  • Redundant output signal for safety applications
  • Low installation height, easy to install
  • Ingress protection: IP67
Datasheet
User Manual

  • Measuring ranges 0 ... 280 kN to 0 ... 2,060 kN
  • Insensitive to lateral forces
  • Stainless steel version (corrosion-resistant)
  • Integrated amplifier
  • High long-term stability, high shock and vibration resistance, good reproducibility
Datasheet

  • Measuring ranges 0 ... 100 N to 0 ... 36 kN
  • Relative linearity error ±1.0 ... 1.6 % Fnom with analogue pressure gauge, ±0.5 % Fnom with digital pressure gauge or pressure sensor1)
  • Piston stroke ≤ 0.5 mm
  • Operates without supply voltage
  • 5-year leak-tightness warranty2)
Datasheet
User Manual

  • Measuring ranges 0 ... 200 N to 0 ... 100 kN
  • Relative linearity error 0.5 % Fnom
  • Stainless steel version
  • Low installation height, easy to install
  • Ingress protection IP66
Datasheet
User Manual

  • Measuring ranges 0 ... 50 N to 0 ... 5 kN
  • Relative linearity error 0.5 % Fnom
  • Material: Stainless steel
  • Low installation height, easy to install
  • Ingress protection IP65
Datasheet
User Manual

  • Measuring ranges 0 ... 50 N to 0 ... 1,000 N
  • Relative linearity error 1 % Fnom
  • Stainless steel or aluminium version
  • Low installation height, easy to install
  • Ingress protection IP64
Datenblatt
Bedienungsanleitung

  • Measuring ranges 0 ... 2.5 kN to 0... 300 kN
  • Relative linearity error 0.1 % Fnom
  • Stainless steel version, completely welded
  • Low installation height, easy to install
  • Ingress protection IP67
Datasheet
User Manual

  • Measuring ranges 0 ... 0.02 kN to 0 ... 2,200 kN (0 ... 5 lbs to 0 ... 500,000 lbs)
  • Robust version
  • Material: Stainless steel
  • Ingress protection as of IP66
  • Relative linearity error as of 0.1 % Fnom
Datasheet

  • Measuring ranges 0 … 1 kN up to 0 ... 500 kN
  • Simple force introduction
  • Compact small dimensions
  • Protection class IP65
  • Relative linearity error 1 % Fnom
Datasheet

  • Measuring ranges 0 ... 10 N up to 0 ... 5,000 N
  • Ease of force input, easy installation
  • Compact and small dimensions, low installation height
  • Protection class IP65
  • Relative linearity error 1 % Fnom
Datasheet

  • Measuring ranges 0 ... 1 kN up to 0 ... 1,000 kN
  • For compression force measurements
  • Simple force introduction, easy installation
  • Protection class IP67
  • Relative linearity error 0.3 % Fnom (0.1 % Fnom optional)
Datasheet

  • Measuring ranges 0 ... 6 kN to 0 ... 850 kN
  • Relative linearity error ±1.0 ... 1.6 % with analogue pressure gauge, ±0.5 % with digital pressure gauge or pressure sensor1)
  • Piston stroke ≤ 0.5 mm
  • Operates without supply voltage
  • 5-year leak-tightness warranty2)
Datasheet

  • Measuring ranges 0 ... 1.2 kN to 0 ... 500 kN
  • Flattened case for stable measurement
  • Relative linearity error ±1.0 ... 1.6 % Fnom with analogue pressure gauge, ±0.5 % Fnom with digital pressure gauge or pressure sensor1)
  • Operates without supply voltage
  • 5-year leak-tightness warranty2)
Datasheet
User Manual

  • Measuring ranges 0 ... 2 kN to 0 ... 480 kN
  • Relative linearity error ±1.0 ... 1.6 % with analogue pressure gauge, ±0.5 % with digital pressure gauge or pressure sensor1)
  • Piston stroke ≤ 0.5 mm
  • Operates without supply voltage
  • 5-year leak-tightness warranty2)
Datasheet
User Manual

  • Measuring ranges 0 ... 4 kN to 0 ... 400 kN
  • Relative linearity error ±1.0 ... 1.6 % with analogue pressure gauge, ±0.5 % with digital pressure gauge or pressure sensor1)
  • Piston stroke ≤ 0.8 mm
  • Operates without supply voltage
  • 5-year leak-tightness warranty2)
Datasheet
User Manual

  • Measuring ranges 0 ... 6 kN to 0 ... 1,000 kN
  • Relative linearity error ±1.0 ... 1.6 % Fnom with analogue pressure gauge, ±0.5 % Fnom with digital pressure gauge or pressure sensor1)
  • Piston stroke ≤ 0.5 mm, force introduction as total clamping force
  • Operates without supply voltage
  • 5-year leak-tightness warranty2)
Datasheet

  • Measuring ranges 0 ... 5 t to 0 ... 30 t
  • 1,000 intervals per OIML R60 Class C
  • Measuring element from stainless steel
  • Hermetically sealed and welded, ingress protection IP68
Datasheet
User Manual

  • Measuring ranges 0 ... 320 N to 0 ... 120 kN
  • Flattened case for stable measurement
  • Relative linearity error ±1.0 ... 1.6 % Fnom with analogue pressure gauge, ±0.5 % Fnom with digital pressure gauge or pressure sensor1)
  • Operates without supply voltage
  • 5-year leak-tightness warranty2)
Datasheet
User Manual

  • Measuring ranges 0 ... 320 N to 0 ... 120 kN
  • Relative linearity error ±1.0 ... 1.6 % Fnom with analogue pressure gauge, ±0.5 % Fnom with digital pressure gauge or pressure sensor1)
  • Piston stroke ≤ 0.5 mm
  • Operates without supply voltage
  • 5-year leak-tightness warranty2)
Datasheet
User Manual

  • Measuring ranges 0 ... 2.5 kN to 0 ... 470 kN
  • Relative linearity error ±1.0 ... 1.6 % Fnom with analogue pressure gauge, ±0.5 % Fnom with digital pressure gauge or pressure sensor1)
  • Piston stroke ≤ 0.5 mm, force introduction as total clamping force
  • Operates without supply voltage
  • 5-year leak-tightness warranty2)
Datasheet

  • Measuring ranges 0 ... 160 N to 0 ... 60 kN
  • Relative linearity error ±1.0 ... ±1.6 % Fnom with analogue pressure gauge, ±0.5 % Fnom with digital pressure gauge or pressure sensor
  • Piston stroke ≤ 0.5 mm
  • Operates without supply voltage
  • 5-year leak-tightness warranty
Datasheet
User Manual

  • Measuring ranges 0 ... 1.1 kN to 0 ... 180 kN
  • Relative linearity error ±1.0 ... 1.6 % Fnom with analogue pressure gauge, ±0.5 % Fnom with digital pressure gauge or pressure sensor1)
  • Piston stroke ≤ 0.5 mm, force introduction as total clamping force
  • Operates without supply voltage
  • 5-year leak-tightness warranty2)
Datasheet

  • Measuring ranges 0 ... 100 N to 0 ... 36 kN
  • Relative linearity error ±1.0 ... 1.6 % Fnom with analogue pressure gauge, ±0.5 % Fnom with digital pressure gauge or pressure sensor1)
  • Piston stroke ≤ 0.5 mm
  • Operates without supply voltage
  • 5-year leak-tightness warranty2)
Datasheet
User Manual

 

Flow measurement of fuels, coolants, and other critical liquids is crucial for the efficiency and safety of operations. Flow meters must be accurate and reliable under a variety of operating conditions.

Volumetric flow rate Min.: 100 l/min (26.4 us gal/min) Max.: 20,000 l/min (5,283.4 us gal/min)

Datasheet

The HySense® CL 1xx is a high intelligence sensor that not only determines oil level precisely, but also measures the following oil condition parameters: relative humidity, relative permittivity, conductivity, and temperature. After a calibration phase, this sensor can evaluate an oil’s condition and output it based on implemented condition algorithms. Moreover, the corresponding analysis application that is implemented in MultiSystem measuring devices makes it enormously easier to operate and use the sensors. Finally, the intuitive menu navigation and the stored oil database both make it easy to quickly acquire, visualize, evaluate, and store oil condition parameters

Datasheet
Catalog Excerpt

 

Speed and position measurement are essential for navigation and control. High-precision gyroscopes, accelerometers, and GPS systems provide crucial data for flight control and navigation.

  • Interchangeable reference sensors that can be changed via the front
  • Large colour touchscreen with all necessary information
  • Control stability 0.001 % of span
  • Accuracy up to 0.009 % IS-50 (IntelliScale)
Datasheet

Up to 15mm stroke

The position sensor HySense® PO 180 works on the measuring wire principle. It can be easily mounted and does not need linear guiding. At the measuring wire principle, a specially manufactured and calibrated wire is tightly wound around a high-precision drum that is driven against the pulled direction by a spring motor. Through the detection of the winding process the sensor converts the linear movement into an electrical signal. All mechanical and electronic components are protected by a solid casing. It is available for several measurement ranges from 0-3000 mm. Areas of application could be e. g.: Load cranes Hydraulic presses Your benefit at a glance: Compact High resolution and accuracy High dynamic Insensitive to environmental influences

  • SchutzartIP67
  • Meßbereiche: 0...100mm bis 0...3000mm
  • MitAnalogausgang0…10V,4…20mA,Poti oderA/D-Wandler-Ausgangsynchron-seriell(SSI)
Datasheet

 

Environmental testing includes a series of tests to ensure that components and systems function reliably under extreme conditions such as vacuum, radiation, high g-forces, and temperature extremes. These tests range from thermal vacuum tests to vibration and shock tests, as well as radiation resistance tests.

  • shows you where the leak is on the screen
  • Find leaks during production without interruption of plant operation
  • very intuitive and no training required!
  • let’s you hear where the compressed air leak is also on the headphones
  • 5 LED’s and ambient light sensor for intelligent lighting in dark environments
  • Leak estimation function (l/min or cfm) and (Cost per Year)
  • Running time of 7 hours of the ILD 500/ ILD 510
  • Lightest acoustic camera on the market with 600 gr
  • can be connected to existing ILD 500/ ILD 510
Datasheet
User Manual

  • 136 Low-noise MEMS Microphones, real-time sound source localization
  • Real-time estimated leak rate, leak cost, and leak level for gas leak detection
  • Partial discharge detection can identify corona, floating, surface, and particle discharges
  • Analyzer acoustic software for analyzing images and export reports
  • 800 × 480 Resolution, 4.3’LCD Touch Screen
  • Supports 8 acoustic palettes
Datasheet
Flyer
User Manual

The Gas-Pro IR is ideal for the oil and gas industry. This personal multigas monitor can detect methane, pentane or propane using infrared (IR) sensor technology. The Gas-Pro IR is ideal for detecting potentially explosive gases where traditional, ”pellistor”, catalytic sensors will struggle – especially in a low oxygen environment.



Datasheet

 

Quality control and material testing are crucial to ensure that all materials and components used meet the stringent requirements of the aerospace industry. This includes non-destructive testing (NDT), metallography, and spectroscopic analyses.

  • Interchangeable reference sensors that can be changed via the front
  • Large colour touchscreen with all necessary information
  • Control stability 0.001 % of span
  • Accuracy up to 0.009 % IS-50 (IntelliScale)
Datasheet

The DPI610E not only delivers highly accurate measurements – it does so for a wide variety of pressure ranges (350mbar / 5 psi / 33 kPa to 1000bar /15000 psi / 100 MPa ). That means one device can cover all your calibration needs – reducing both cost of ownership and maintenance.



Datasheet
User Manual
Quick Start

 

The advanced measurement and testing technology in the aerospace industry enables engineers and technicians to maximize performance, enhance safety, and ensure compliance with strict international standards and regulations.