Granule processing

alexander grey ooxMySOfRRU unsplash min

Foto by Alexander Grey on Unsplash

 

The effective drying and dedusting of plastic granules is essential for the production of high-quality plastic parts. Often, the granules are already contaminated with dust and fibers (also known as angel hair) due to abrasion during delivery. These impurities can lead to quality defects in the end product, especially in products that require high optical quality or a high-gloss finish. In severe cases, such impurities can even cause product jams and thus downtime of production facilities. Our pressure measurement technology offers precise monitoring of the vacuum in dedusting systems to minimize such risks.

Another critical aspect is the adequate drying of hygroscopic thermoplastics to bring them to an optimal residual moisture content for processing. This is achieved through special air treatment, which ensures an extremely low dew point and thus a minimal absolute water content. WIKA’s temperature measurement devices contribute to an energy-efficient operation of the drying plants, while our level measurement devices control the material fill level in the drying container. Pressure gauges, on the other hand, ensure efficient air conveyance through the blower.

  • Reliable and cost-effective
  • Design per EN 837-1 or ASME B40.100
  • Nominal size 40 [1 ½"], 50 [2"], 63 [2 ½"], 80 [3"], 100 [4"] and 160 [6"]
  • Scale ranges to 0 ... 400 bar [0 ... 6,000 psi]
Datasheet

  • Long service life, robust
  • Cost-effective and reliable
  • To combine with WIKA diaphragm seals
  • German Lloyd approval
  • Scale ranges up to 0 … 1,000 bar
Datasheet
User Manual
User Manual

  • Good/bad indication through parameterisable digital display (red/green)
  • Compact size enables easy installation in narrow spaces
  • Optimised design makes OEM machine integration easier
  • Designed for rough demands of up to 50 g shock and -40 ... +125 °C [-40 ... +257 °F]
Datasheet
User Manual

  • Adjustable switch hysteresis
  • Setting ranges: 0.2 … 2 bar [3 ... 30 psi] to 30 ... 320 bar [450 ... 4,600 psi] and -0.85 ... -0.15 bar [-25 inHg ... -5 inHg]
  • Non-repeatability of the switch point: ≤ 2 %
  • Switching functions: Normally closed, normally open or change-over contact
  • Media: Compressed air, neutral and self-lubricating fluids and neutral gases
Datasheet

  • Zero point setting in front
  • Special connection location on request
  • Low scale ranges from 0 ... 25 mbar
Datasheet
User Manual

  • Measuring ranges from 0 … 0.05 to 0 … 1,000 bar
  • Non-linearity 0.25 % or 0.5 %
  • Output 4 ... 20 mA, DC 0 ... 10 V, DC 0 ... 5 V and others
  • Electrical connection: Angular connector form A and C, circular connector M12 x 1, cable outlet 2 m
  • Process connection G ¼ A DIN 3852-E, ¼ NPT and others
Datasheet
User Manual

  • Wetted parts from stainless steel
  • Resistant to all common refrigerants
  • Special case design for the best possible condensation tightness
  • Private labelling possible
Datasheet
User Manual

  • Industry 4.0-ready IO-Link sensor improves connectivity and diagnostics
  • Designed for rough demands of up to 1,000 g shock and -40 ... +125 °C [-40 ... +257 °F]
  • Optimised design makes OEM machine integration easier
  • Multicolour 360° LED status display simplifies troubleshooting and localisation
Datasheet
User Manual

  • Measuring ranges from 0 ... 6 bar to 0 ... 600 bar
  • Non-linearity 0.5 %
  • Standard industrial signals
  • Electrical connection: Angular connector form A and C, circular connector M12 x 1, Metri-Pack series 150, cable outlet 2 m unshielded or shielded
  • Many internationally customary process connections
Datasheet
User Manual

  • Measurement ranges 0 ... 3 kg up to 0 ... 250 kg
  • Made of aluminum alloy
  • High accuracy
  • High side load tolerance
  • Simple structure, easy to install
Datasheet
User Manual

  • Measuring ranges 0 … 20 kg up to 0 ... 500 kg
  • Made of aluminum
  • High accuracy
  • Insensitive to side and corner loads
  • Simple structure, easy to install
Datasheet
User Manual

  • Measuring ranges 0 … 0.3 kg up to 0 ... 10 kg
  • Made of aluminum alloy
  • High accuracy
  • Insensitive to side and corner loads
  • Simple structure, easy to install
Datasheet
User Manual

  • Measuring ranges 0 … 500 kg up to 0 ... 10.000 kg
  • Steel/stainless steel
  • High long-term stability
  • High side load tolerance
Datasheet

  • Measuring ranges 0 … 5 kg up to 0 ... 500 kg
  • Completely welded bellows
  • Protection class IP68
Datasheet

  • Measuring ranges 0 ... 2 kN up to 0 ... 100 kN
  • Corrosion-resistant stainless steel design
  • Integrated amplifier
  • High long-term stability, high shock and vibration resistance
  • Good reproducibility, simple installation
Datasheet
User Manual

  • Accuracy class 2 per EN 13190
  • Nominal size 63, 80, 100 and 160
  • Scale ranges from -30 ... +200 °C
Datasheet
User Manual

  • Measuring ranges from -50 ... +200 °C [-58 ... +392 °F]
  • Electrical connection via plug connection
  • Output signal 4 … 20 mA or 0 … 10 V
  • Factory configured
  • Measuring insert exchangeable
Datasheet
User Manual

  • Very compact design, high vibration resistance and fast response time
  • With direct sensor output (Pt100, Pt1000 in 2-, 3- or 4-wire connection) or integrated transmitter with 4 ... 20 mA output signal
  • Integrated transmitter is individually parameterisable with free-of-charge WIKAsoft-TT PC configuration software
  • Sensor element with accuracy class A per IEC 60751


Datasheet
User Manual

  • Measuring ranges from -50 ... +250 °C [-58 ... +482 °F]
  • Very high vibration resistance
  • Compact design
  • Electrical connection via plug connection
Datasheet
User Manual

  • Scale ranges from -30 ... +500 °C
  • Large choice of nominal sizes from 25 ... 160 mm
  • Case and stem from stainless steel
  • 5 different connection designs
Datasheet
User Manual