Water and Wastewater

patrick federi bjcceKhRsqA unsplash

Photo by Patrick Federi on Unsplash

 

Water and wastewater are fundamental aspects of urban infrastructure, encompassing both the supply of clean water to the community and the efficient, environmentally friendly treatment of wastewater. In municipal water supply, various technologies are employed to extract raw water from natural sources and then treat it to become drinking water or utility water. The entire process involves several steps: the extraction of raw water, its treatment, storage, and finally, distribution to consumers.

Precise measuring instruments are required for the monitoring and control of these processes. These include pressure measuring devices used at various stages of water extraction and distribution, as well as thermometers and level probes for temperature and level monitoring. These instruments are essential to ensure the efficiency and safety of the water supply.

In municipal wastewater treatment, similar measuring instruments are used to monitor and control a multitude of processes. This includes treatment in overflow and rainwater retention basins, aeration, sedimentation and settling basins, as well as other facilities such as screening plants, filter presses, and digestion towers. Accurate monitoring of these processes is crucial for reducing environmental impact and complying with legal regulations.

In industrial wastewater treatment, the requirements are often even more specific, driven by regulatory mandates such as the IPPC Directive, which demands the use of the best available techniques (BAT) to optimize wastewater discharge. The use of cutting-edge measuring technology in wastewater treatment plants allows industrial companies to efficiently monitor and optimize their processes, ensuring compliance with these requirements.

Application examples in both municipal and industrial water treatment include level measurement in wells, high/low reservoirs, and open waters, monitoring of filters, operation of pumping stations and pressure boosting systems, and network pressure monitoring. These applications demonstrate the diversity and crucial role of precise measuring instruments in maintaining a safe and efficient water and wastewater supply.

  • Safety version with solid baffle wall designed in compliance with the requirements and test conditions of EN 837-1
  • Excellent load-cycle stability and shock resistance
  • Completely from stainless steel
  • Scale ranges from 0 … 0.6 to 0 … 1,600 bar
Datasheet
User Manual
User Manual
User Manual
User Manual

  • Lateral installation in the tank
  • Operating limits:- Operating temperature: T = -40 ... +120 °C- Operating pressure: P = 5 bar - Limit density: ρ ≥800 kg/m3
  • Plastic and stainless steel versions
  • Space-saving installation
  • Switch consists of only one component
Datasheet
User Manual

  • Manual pressure generation of -0.85 … +25 bar [12.3 ... +360 psi]
  • Accuracy: 0.025 % FS (incl. calibration certificate)
  • Generation/measurement of 0 ... 24 mA and voltage supply DC 24 V
  • Data logger with high measuring rate and large memory
  • Intrinsically safe version

  • Sensor ranges from -196 ... +600 °C [-320 ... +1,112 °F]
  • For insertion or screw-in with optional process connection
  • Cable from PTFE, PFA, silicone and other cable sheath materials
  • Versions with/without connector or connection housing (option)
  • Explosion-protected versions are available for many approval types (see data sheet page 2)


Datasheet
User Manual
User Manual
User Manual
User Manual

  • Case aluminium, epoxy resin coated
  • Ingress protection IP 65, NEMA 4
  • Ambient temperature -40 ... +85 °C
  • 1 switch point, SPDT or DPDT with a high contact rating of up to 15 A / AC 220 V
  • Capillary up to 10 m



Datasheet
User Manual

  • Completely round, no corners and edges
  • For direct installation between two flanges
  • Wide choice of special materials
Datasheet
User Manual

  • No power supply needed for switching of electrical loads
  • Robust switch enclosure from 316L, IP66/NEMA 4X
  • Setting ranges from 0 ... 25 mbar abs. up to 0 ... 1.5 bar abs.
  • Intrinsic safety Ex ia available
  • 1 or 2 independent set points, SPDT or DPDT, high switching power up to AC 250 V, 20 A
Datasheet
User Manual

  • No power supply needed for switching of electrical loads
  • Robust switch enclosure from stainless steel 316L, IP66, NEMA 4X
  • Setting ranges from 0 ... 16 mbar to 0 ... 40 bar with high static and high one-sided pressure up to 160 bar
  • Intrinsic safety Ex ia available
  • 1 or 2 independent set points, SPDT or DPDT, high switching power up to AC 250 V, 20 A
Datasheet
User Manual

  • Intrinsically safe Ex i version, very compact design, high vibration resistance and fast response time
  • With direct sensor output (Pt100, Pt1000 in 2-, 3- or 4-wire connection) or integrated transmitter with 4 ... 20 mA output signal
  • Integrated transmitter is individually parameterisable with free-of-charge WIKAsoft-TT PC configuration software
  • Sensor element with accuracy class A per IEC 60751


Datasheet
User Manual

  • Multi-functional display
  • Simple menu navigation
  • Conductive plastic case
  • Large LC display, rotatable
  • Approvals for hazardous areas
Datasheet
User Manual

  • Precise and reliable
  • Integrated temperature measurement (option)
  • Design out of Hastelloy® and FEP cable for especially high resistance (option)
  • Ingress protection IP68 permanently up to 300 m water column
Datasheet
Datasheet
User Manual

  • Case aluminium, epoxy resin coated
  • Ingress protection IP 65, NEMA 4
  • Ambient temperature -40 ... +85 °C
  • 1 switch point, SPDT or DPDT with a high contact rating of up to 15 A/AC 220 V
  • Capillary up to 10 m



Datasheet
User Manual

  • No configuration necessary due to “plug-and-play”
  • Scale ranges from 0 … 25 mbar absolute pressure
  • Easy-to-read analogue display with nominal sizes 100 and 160
  • High overload safety, long service life due to metallic media chamber sealing
  • Media chamber protected against unauthorised access
Datasheet
User Manual

  • Differential pressure measuring ranges from 0 … 60 mbar
  • High working pressure (static pressure) and high overload safety, selectable up to 40, 100, 250 or 400 bar
  • Measuring cell liquid dampening against rapid pressure changes
  • Instruments with inductive contacts for use in hazardous areas
  • Instruments with switch contact for PLC applications
Datasheet
User Manual
User Manual

  • Compact design, no moving components
  • Temperature ranges from -30 … +135 °C
  • Versions for pressure ranges from vacuum to 50 bar
  • Mounting position as required
  • Visual indication of the switching status
Datasheet
User Manual

  • High overload safety, optionally up to 40, 100 or 400 bar, due to the metallic pressure element limit stop, without liquid-filled measuring cell
  • Wide choice of special materials
  • Also available with liquid-filled case for high dynamic pressure loads or vibrations
  • Instruments with inductive contacts for use in hazardous areas
  • Instruments with switch contact for PLC applications
Datasheet
User Manual
User Manual

  • No power supply needed for switching of electrical loads
  • Setting ranges from -30 ... +70°C up to 0 ... 600 °C
  • Robust switch enclosure from aluminium alloy, IP 66, NEMA 4X
  • 1 or 2 independent set points, SPDT or DPDT, high switching power up to AC 250 V, 20 A
  • Remote mounting with capillary ≤ 10 m



Datasheet
User Manual

  • LC display
  • Variants with sensors for insertion, mounting into a thermowell or with contact bulb for mounting on a pipe surface
  • For all standard thermowell designs
  • Measuring range -40 ... +450 °C (-40 ... +842 °F)
  • With automatic measuring range changeover (Autorange)
Datasheet
User Manual

  • Versions for Pt100 / Pt1000 or thermocouples
  • Output 0 ... 10 V, 3-wire (T91.10) or 4 ... 20 mA, 2-wire (T91.20)
  • Error signalling in the event of sensor break
  • High accuracy
  • Compact and value for money
Datasheet
User Manual

  • Suitable for measurements in contaminated and aggressive media
  • An optimised discharge behaviour and a large pressure port prevent the instrument from clogging and ensure a
    minimum maintenance effort
  • Can be used in explosion-protected areas
  • Developed for wireless applications
Datasheet
User Manual
User Manual

  • Simple mounting of the illumination system
  • Illumination types available for different applications
  • Operating temperature: depending on illumination method
  • Matching to the respective length of the glass indicator
Datasheet
User Manual

  • Double-diaphragm system to ensure the separation of the process and the pressure measuring instrument
  • Process connection with thread to provide for direct threaded connection
  • All welded version with internal diaphragm
  • System from Monel
Datasheet
User Manual

  • Process- and procedure-specific production
  • Operating limits: - Operating temperature: T = -196 ... +450 °C - Operating pressure: P = Vacuum up to 400 bar
  • Wide variety of different process connections and materials
  • Mounting of level sensors and guided wave radars possible as an option
Datasheet
User Manual

  • Simplified calibration through removable measuring inserts
  • Materials and surface finish quality in accordance with the standards of hygienic design
  • Stainless steel head in optimised hygienic design, easily cleanable in all mounting positions (patent, property right: GM 000984349)
  • Pt100, 4 … 20 mA or HART® protocol



Datasheet
User Manual
User Manual
User Manual
User Manual

  • Flange with flush welded diaphragm
  • Common standards and nominal widths available
  • Wide variety of different materials and material combinations

 

Datasheet
User Manual

  • No configuration necessary due to “plug-and-play”
  • Measuring ranges of up to 0 ... 1,000 bar or 0 ... 15,000 psi
  • Easy-to-read analogue indication with nominal size 63
  • Safety version with solid baffle wall (Solidfront) designed in compliance with the requirements of EN 837-1 and ASME B40.100
  • Patents and property rights, e.g. US 8030990, DE 112007000980, CN 101438333
Datasheet
User Manual

  • Differential pressure measuring ranges from -1 … +30 bar [-14.5 ... 435 psi] to 0 ... 40 bar [0 ... 580 psi]
  • High working pressure (static pressure) and high overload safety, selectable 40 bar [580 psi], 100 bar [1,450 psi], 250 bar [3,625 psi], 400 bar [5,800 psi] and 650 bar [9,425 psi]
  • The transmission fluid in the measuring chamber dampens the indicator in case of high changes of the rate of pressure
  • Model 73x.14: Stainless steel version
  • Model 76x.14: Version with special materials
Datasheet
User Manual
User Manual

  • Process connection with thread for direct threaded connection
  • Version with internal diaphragm
  • Diaphragm seal parts screwed together
  • Universal application
Datasheet
User Manual

  • No power supply needed for switching of electrical loads
  • Setting ranges from -15 ... +20 °C to 180 ... 250 °C
  • Repeatability of the set point ≤ 1% span
  • 1 set point, SPDT, high switching power up to AC 250 V, 5 A
  • Direct mounting or remote mounting with capillary ≤ 10 m



Datasheet
User Manual

  • No power supply needed for switching of electrical loads
  • Robust switch enclosure from 316L, IP 66, NEMA 4X
  • Setting ranges from 0 ... 2.5 bar up to 0 ... 1,000 bar, vacuum ranges
  • Ex ia version available
  • 1 or 2 independent set points, SPDT or DPDT, high switching power up to AC 250 V, 20 A
Datasheet
User Manual

  • No power supply needed for switching of electrical loads
  • Robust switch enclosure from aluminium alloy, IP66, NEMA 4X
  • Setting ranges from 0 ... 16 mbar to 0 ... 40 bar with high static and high one-sided pressure up to 160 bar
  • Repeatability: ≤ 1 % of span
  • 1 or 2 independent set points, SPDT or DPDT, high switching power up to AC 250 V, 20 A
Datasheet
User Manual

  • Electropolished case
  • Ingress protection IP 65, NEMA 4
  • Ambient temperature -40 ... +85 °C
  • 1 or 2 independent switch points, high contact rating up to 15 A / AC 220 V
  • Directly connected or via capillary (up to 10 m capillary)




Datasheet
User Manual

  • Case from AISI 316 (1.4401)
  • Ingress protection IP 66, NEMA 4
  • Ambient temperature -40 ... +85 °C
  • 1 switch point, SPDT, up to 5 A/AC 220 V
  • Directly connected or via capillary (up to 10 m capillary



Datasheet
User Manual

  • Safety pressure gauge with solid baffle wall designed in compliance with the requirements and test conditions of EN 837-1
  • Completely from stainless steel
  • Knife edge pointer for optimal accuracy of reading
  • Wear-resistant precision movement from stainless steel
  • Scale ranges from 0 … 0.6 to 0 … 1,600 bar [0 ... 10 psi to 0 ... 20,000 psi]
Datasheet
User Manual
User Manual

  • Installation of head-mounted transmitters in the connection housing possible
  • Wide variety of different electrical connections, process connections, materials and contact separations
  • Programmable and configurable head-mounted transmitters for 4 ... 20 mA, HART®, PROFIBUS® PA or FOUNDATION™ Fieldbus field signals
  • Explosion-protected versions
  • Temperature ranges from -100 … +350 °C
Datenblatt
Datenblatt
Datenblatt
Bedienungsanleitung
Bedienungsanleitung
Bedienungsanleitung

  • High overload safety up to 50 x full scale value
  • High reliability and long service life
  • Up to 4 switch contacts per instrument
  • Instruments with inductive contacts for use in hazardous areas
  • Instruments with switch contact for PLC applications
Datasheet
User Manual
User Manual

  • Fully welded mounting ring to prevent water ingress into the control panel (ingress protection IP66)
  • All stainless steel construction
  • Optionally as safety version "S3" per EN 837-1
Datasheet
User Manual
User Manual
User Manual

  • Very compact design, high vibration resistance and fast response time
  • With direct sensor output (Pt100, Pt1000 in 2-, 3- or 4-wire connection) or integrated transmitter with 4 ... 20 mA output signal
  • Integrated transmitter is individually parameterisable with free-of-charge WIKAsoft-TT PC configuration software
  • Sensor element with accuracy class A per IEC 60751


Datasheet
User Manual

  • No power supply needed for switching of electrical loads
  • Robust switch enclosure from aluminium, IP66, NEMA 4X
  • Setting ranges from 0 ... 25 mbar abs. to 0 ... 1.5 bar abs.
  • Repeatability: ≤ 1 % of span
  • 1 or 2 independent set points, SPDT or DPDT, high switching power up to AC 250 V, 20 A
Datasheet
User Manual

  • Very compact design, high vibration resistance and fast response time
  • With direct sensor output (Pt100, Pt1000 in 2-, 3- or 4-wire connection) or integrated transmitter with 4 ... 20 mA output signal
  • Integrated transmitter is individually parameterisable with free-of-charge WIKAsoft-TT PC configuration software
  • Sensor element with accuracy class A per IEC 60751


Datasheet
User Manual
User Manual
User Manual

  • Accuracy up to 0.025 % IS-50
  • Measuring range from -1 ... +400 bar (-15 ... +6,000 psi)
  • Output mode 250 Hz (4 ms) response time
  • Streaming output mode in IEEE-754 format
Datasheet
User Manual

  • Large range of application due to the simple, proven functional principle
  • For harsh operating conditions, long service life
  • Operating limits: - Operating temperature: T = -120 ... +350 °C - Operating pressure: P = Vacuum to 232 bar - Limit density: ρ ≥ 500 kg/m3
  • Stainless steel and plastic versions
  • Explosion-protected versions
Datasheet
User Manual
User Manual
User Manual

  • Excellent load-cycle stability and shock resistance
  • All stainless steel construction
  • German Lloyd approva
  • Scale ranges up to 0 … 1,600 bar
Datasheet
User Manual
User Manual
User Manual
User Manual

  • TÜV zertifizierte SIL-Version für Schutzeinrichtungen entwickelt nach IEC 61508 (Option)
  • Einsatz in Sicherheitsanwendungen bis SIL 2 (einzelnes Gerät) und SIL 3 (redundante Verschaltung)
  • Konfigurierbar mit nahezu jedem offenen Soft- und Hardwaretool
  • Universell für den Anschluss von 1 oder 2 Sensoren - Widerstandsthermometer, Widerstandssensor - Thermoelement, mV-Sensor - Potentiometer
  • Signalisierung gemäß NAMUR NE43, Sensorbruchüberwachung gemäß NE89, EMV gemäß NE21
Datenblatt
Bedienungsanleitung

  • Case and wetted parts from stainless steel
  • Wide choice of special materials
  • High overload safety up to the 10-fold full scale value
  • Process connection thread or open flange
  • Scale ranges from 0 … 16 mbar
Datasheet
User Manual
User Manual
User Manual

  • High overload safety
  • Long service life due to metal media chamber sealing and the extremely gas-tight material of the reference chamber
  • Instruments compatible with switch contacts
  • Scale ranges from 0 … 25 mbar absolute pressure
Datasheet
User Manual
User Manual

  • Suitable for liquid, gas and steam flow measurement
  • Accuracy ≤ ±0.5 % of actual flow rate
  • Repeatability of measurement 0.1 %
  • Lowest pressure loss in the family of primary flow elements
  • Calibration may be performed if required
Datasheet
User Manual

  • Pressure ranges: from 0 ... 25 mbar up to 0 ... 2,890 bar [0 ... 0.36 up to 0 ... 42,000 psi]
  • Accuracy down to 0.008 % of IS (IntelliScale)
  • External pressure ranges from 25 mbar ... 1,000 bar [0.36 ... 15,015 psi]
  • Precision 0.004 % FS
  • Removable/interchangeable sensors

Datasheet
User Manual

  • Zero point correction in front
  • Completely from stainless steel
  • With liquid-filled case for applications with high dynamic pressure loads and vibrations (model 633.50)
  • Low scale ranges from 0 ... 2.5 mbar to 0 ... 600 mbar or 0 ... 1 inH2O to 0 ... 240 inH2O
Datasheet
User Manual
User Manual

  • Measuring ranges from -50 ... +200 °C [-58 ... +392 °F]
  • Electrical connection via plug connection
  • Output signal 4 … 20 mA or 0 … 10 V
  • Factory configured
  • Measuring insert exchangeable
Datasheet
User Manual

  • Process- and procedure-specific production
  • Operating limits: - Operating temperature: -196 ... +374 °C 1) - Operating pressure: Vacuum to 250 bar 1)
  • Wide variety of different process connections and materials
  • Illumination optional
  • Heating and/or insulation optional
Datasheet
User Manual
User Manual

  • Very good vibration and shock resistance
  • Especially robust design
  • Type approval for the shipbuilding industry
  • Scale ranges to 0 ... 1,000 bar or 0 ... 15,000 psi
Datasheet
User Manual
User Manual
User Manual

  • For the connection of Pt100 and Pt1000 sensors in a 2-, 3- or 4-wire connection
  • For the connection of reed chains in a potentiometer circuit
  • Parameterisation with the WIKAsoft-TT configuration software and electrical connection via quick connector magWIK
  • Connection terminals also accessible from the outside
  • Accuracy < 0.2 K (< 0,36 °F) / 0.1 %
Datasheet
User Manual

  • Large range of application due to the simple, proven functional principle
  • For harsh operating conditions, long service life
  • Operating limits: - Operating temperature: T = -50 ... +350 °C - Operating pressure: P = Vacuum up to 40 bar - Limit density: ρ ≥ 300 kg/m3
  • Wide variety of different electrical connections, process connections and materials
  • Explosion-protected versions
Datasheet
Datasheet
User Manual
User Manual
User Manual

  • Transmission of process values to the control room (e.g. 4 ... 20 mA)
  • Shatterproof window and robust aluminium or stainless steel measuring chamber for increased requirements
  • Optionally with approvals for hazardous areas
  • High ingress protection, IP65, for outdoor use and processes with high condensation
  • Low measuring range from 0 ... 160 mbar
Datasheet
User Manual

  • No power supply needed for switching of electrical loads
  • Robust switch enclosure from aluminium alloy or stainless steel with identical dimensions, IP66, NEMA 4X
  • Setting ranges from 0.2 ... 1.2 to 200 ... 1,000 bar, vacuum ranges
  • Repeatability of the set point ≤ 1% of span
  • 1 set point, SPDT or DPDT, high switching power up to AC 250 V, 15 A
Datasheet
User Manual

  • Reliable and cost-effective
  • Design per EN 837-1 or ASME B40.100
  • Nominal size 40 [1 ½"], 50 [2"], 63 [2 ½"], 80 [3"], 100 [4"] and 160 [6"]
  • Scale ranges to 0 ... 400 bar [0 ... 6,000 psi]
Datasheet

  • Suitable for all level measurements in hazardous areas
  • Explosion protection in accordance with IECEx, ATEX and CSA
  • Shipbuilding approval in accordance with GL
  • Ingress protection IP68 up to 300 m immersion depth
Datasheet
Datasheet
User Manual

  • Process connection with thread to provide for direct threaded connection
  • Version with internal diaphragm
  • Diaphragm seal parts all welded
  • Universal application
Datasheet
User Manual

  • Low-wear design due to non-rotating spindle tip in the bonnet
  • Low torque and smooth operation of valve handle even at high pressure
  • Enhanced safety due to blow-out proof bonnet design
  • Customer-specific combination of valves and instruments (hook-up) on request
  • Standardised centre distances of 37 mm and 54 mm, suitable for WIKA differential pressure gauges and commonly used process transmitters
Datasheet
User Manual

  • Proper functioning, even under extreme environmental influences, e.g. dirt, humidity, gases, dust, chips
  • Compact and operationally safe design
  • Mounting of the switches at the magnetic display with T-slot or with tightening strap
  • Process temperature of -60 ... +380 °C (depending on version)
Datasheet
Datasheet
User Manual
User Manual
User Manual

  • Recording interval adjustable from 1 ms ... 10 s
  • Measuring ranges from 0 … 25 mbar to 0 … 1,000 bar (0 ... 0.4 psi to 0 ... 14,500 psi)
  • Accuracy: 0.2 %, optionally 0.1 % (incl. calibration certificate)
  • No external voltage supply required
  • Software for recording of the measured value, calibration and evaluation
Datasheet

  • For waste water, sewage and heavily soiled liquids
  • Environmentally friendly, mercury- and lead-free
  • PP housing
  • High mechanical and electrical durability of micro-switch
  • Suitable for use in hazardous areas Ex zone 0, 1 and 2
Datasheet
User Manual

  • With one or two adjustable microswitches
  • Shatterproof window and robust aluminium or stainless steel measuring chamber for increased requirements
  • Optionally with approvals for hazardous areas
  • High ingress protection, IP65, for outdoor use and processes with high condensation
  • Low measuring range from 0 ... 250 mbar
Datasheet
User Manual

The great advantage of mechanical pressure switches is that no supply voltage is required for the switching process.

  • Compact and slim design
  • Robust switch enclosure from stainless steel 316, IP66, NEMA 4X
  • Wide selection of setting ranges available, 1 … 2.5 bar to 200 … 1,000 bar
  • Set point repeatability of ≤ 1 % for reliable switching
  • High switching power and large selection of contact variants and electrical connections
Datasheet
User Manual

  • High reliability and long service life
  • Wide choice of special materials
  • Up to 4 switch contacts per instrument
  • Also available with liquid filling for high dynamic pressure loads or vibrations
  • Instruments with inductive contacts for use in hazardous areas
  • Instruments with contacts for PLC applications
Datasheet
User Manual

  • Freely selectable switch position through fixing the float switch at the required level
  • Large range of application due to the simple, proven functional principle
  • For harsh operating conditions, long service life
  • Operating limits: - Operating temperature: T = -30 ... +150 °C - Operating pressure: P = Vacuum up to 40 bar - Limit density: ρ ≥600 kg/m3
Datasheet
User Manual

  • Process connection with thread to provide for direct threaded connection
  • Version with internal diaphragm
  • Diaphragm seal parts all welded
  • Universal application
Datasheet
User Manual

  • No power supply needed for switching of electrical loads
  • Robust switch enclosure from aluminium, IP 66, NEMA 4X
  • Setting ranges from 0 ... 2.5 bar up to 0 ... 1,000 bar, vacuum ranges
  • Repeatability of the set point ≤ 0.5% of span
  • 1 or 2 independent set points, SPDT or DPDT, high switching power up to AC 250 V, 20 A
Datasheet
User Manual

  • No configuration necessary due to "plug-and-play"
  • Signal transmission per NAMUR
  • Measuring ranges 0 ... 0.6 bar to 0 ... 1,600 bar
  • Easy-to-read analogue display with nominal size 100 or 160
  • Safety version S3 per EN 837
Datasheet

  • Sensor ranges from -196 ... +600 °C [-320 ... +1.112 °F]
  • Made of mineral-insulated sheathed cable
  • Functional safety (SIL) with model T32 temperature transmitter
  • Spring-loaded design
  • Explosion-protected versions are available for many approval types (see data sheet page 2)




Datasheet
User Manual
User Manual
User Manual
User Manual

  • High working pressure (static pressure) and high overload safety, selectable up to 40, 100, 250 or 400 bar
  • Measuring cell liquid dampening against rapid pressure changes
  • No configuration necessary due to "plug-and-play"
  • Differential pressure measuring ranges from 0 … 60 mbar
  • Individual, non-linear characteristic curves (e.g. x2 or √x for flow measurement)
Datasheet
User Manual

  • Designs per DIN 43772
  • Design TW45-F: Form 5 Design TW45-G: Form 8
Datasheet
User Manual

  • Sensor ranges from -50 ... +500 °C (-58 ... +932 °F)
  • Compact design
  • Spring-loaded tip
  • Explosion-protected versions


Datasheet
User Manual
User Manual
User Manual
User Manual

  • Accuracy up to 0.01 % IS-50
  • Measuring range from -1 ... 400 bar (-15 ... 6,000 psi)
  • RS-232 or RS-485 interface
  • Compact design
Datasheet
User Manual

  • Process- and procedure-specific production
  • Operating limits: - Operating temperature: T = -60 ... +300 °C - Operating pressure: P = Vacuum to 40 bar
  • Wide variety of different process connections
  • Mounting of level sensors and magnetic switches possible as an option
  • Explosion-protected versions
Datasheet
User Manual
User Manual

  • High-quality machining guarantees smooth operation with low torque and low wear
  • Leak-tested tightness in accordance with BS6755 / ISO 5208 leakage rate A
  • Large selection of materials and configurations available
  • Customer-specific combination of valves and instruments (hook-up) on request
Datasheet

  • Shatterproof window and robust aluminium or stainless steel measuring chamber for increased requirements
  • Low scale ranges from 0 ... 160 mbar
  • High accuracy down to 1.6 %
  • Optionally with approvals for hazardous areas
  • Helium leak tested
Datasheet
User Manual

  • Process connection with thread for direct threaded connection
  • Version with internal diaphragm
  • Diaphragm seal parts screwed together
  • Universal application
Datasheet
User Manual

  • Precisely adjustable dual-area spindle pump for filling, pressure generation and fine adjustment of pressure
  • Freely rotating test connections (i.e. measuring instruments can be orientated)
  • Proven technology of the model CPB3800 pressure balance
  • Compact dimensions
  • Low weight
Datasheet
User Manual

  • Application ranges from -50 ... +250 °C [-58 ... +482 °F]
  • Tubular design
  • Spring-loaded design
  • Explosion-protected versions are available for many approval types (see data sheet page 2)


Datasheet
User Manual
User Manual
User Manual
User Manual

  • Overpressure range is indicated completely on scale
  • Safety version with solid baffle wall (Solidfront) designed in compliance with the requirements of EN 837-1 and ASME B40.100
  • With case filling (model 233.36) for applications with high dynamic pressure loads and vibrations
  • Measuring ranges from 0 … 0.6 bis 0 … 40 bar [0 ... 10 to 0 ...600 psi]
Datasheet
User Manual
User Manual

  • Differential pressure measuring ranges from 0 ... 16 mbar to 0 ... 40 bar or 0 ...10 inH2O to 0 ... 600 psi
  • High operating pressure (static pressure) up to 40 bar [600 psi]
  • High overload safety up to 40 bar [600 psi]
  • Models 732.31 and 733.31: Case with safety level “S3” per EN 837
  • All-welded media chamber
Datasheet
User Manual
User Manual

  • Dead space free
  • Hygienic design
  • Aseptic process connections
  • Material and surface finish quality in accordance with pharmaceutical industry directives and standards
Datasheet
User Manual
User Manual
User Manual

  • Completely round, no corners and edges
  • For direct installation between two flanges
  • Wide choice of special materials
Datasheet
User Manual

  • Temperature ranges from -269 … +400 °C
  • Versions for pressure ranges from vacuum to 500 bar
  • Special versions: High pressure, interface measurement
  • Signal processing is made using a separate model OSA-S switching amplifier
Datasheet
Datasheet
User Manual

  • Measured value display by means of rollers or flaps with permanent magnets
  • Medium temperatures from -200 ... +450 °C
  • Splash-proof or hermetically sealed
  • Without power supply
  • Hermetically sealed from the process
Datasheet
Datasheet
Datasheet

  • Sensor ranges from -196 ... +600 °C (-320 ... +1.112 °F)
  • For mounting in all standard thermowell designs
  • Spring-loaded measuring insert (replaceable)
  • Pt100 or Pt1000 sensors
  • Explosion-protected versions
 
Datasheet
User Manual
User Manual
User Manual
User Manual
User Manual

  • Process connection with thread
  • Version with internal diaphragm, diaphragm seal parts screwed together
  • Large selection of process connections and materials
  • Flushing connections optionally available
Datasheet
User Manual

  • Precisely adjustable dual-area spindle pump for filling, pressure generation and fine adjustment of pressure
  • Proven technology of the model CPB3800HP dead-weight tester
  • Compact dimensions
  • Low weight
Datasheet
User Manual

  • Sensor ranges from -50 ... +250 °C [-58 ... +482 °F]
  • For insertion or screw-in with optional process connection
  • Cable from PTFE, PFA, silicone and other cable sheath materials
  • Versions with/without connector or connection housing (option)
  • Explosion-protected versions are available for many approval types (see data sheet page 2)


Datenblatt
Bedienungsanleitung
Bedienungsanleitung
Bedienungsanleitung

  • No configuration necessary due to "plug-and-play"
  • High overload safety up to 50 x full scale value
  • Easy-to-read analogue display with nominal sizes 100 and 160
  • Low measuring error and influence on function from medium pollution
  • Measuring chamber protected against unauthorised intervention
Datasheet
User Manual

  • No configuration necessary due to "plug-and-play"
  • Signal transmission per NAMUR
  • Scale ranges from 0 ... 16 mbar
  • Easy-to-read analogue display with nominal size 100 or 160
  • Safety version "S3" per EN 837
Datasheet
User Manual

  • No power supply needed for switching of electrical loads
  • Robust switch enclosure from stainless steel 316L, IP66, NEMA 4X
  • Setting ranges from 0.3 ... 2.5 mbar to 0.7 ... 16 mbar with high working pressure and high static pressure up to 300 mbar
  • Intrinsic safety Ex ia available
  • 1 set point, SPDT, high switching power up to AC 250 V, 10 A
Datasheet
User Manual

  • High overload safety up to 50 x full scale value
  • Scale ranges from 0 … 2.5 mbar
  • Measuring chamber protected against unauthorised intervention
  • Low measuring error and influence on function from medium pollution
Datasheet
User Manual
User Manual

  • Continuous level measurement on the outside of the bypass
  • 2-wire technology 4 ... 20 mA
  • Measured value output via digital interface and a selectable measured value as analogue signal
  • Case from stainless steel (display from glass)
  • Magnetostrictive level measuring instrument with high resolution
Datasheet
User Manual
User Manual
User Manual

Model CPH6300-S1 (1-channel version) Model CPH6300-S2 (2-channel version)

Datasheet
User Manual

  • Ergonomic handling through the smooth-running, internally operating, precision spindle
  • Integrated oil reservoir
  • Removable star handle
  • Freely rotating test connections (i.e. measuring instruments can be aligned)
  • Integrated priming pump for large test volumes
Datasheet
User Manual

  • Version per DIN 43772
  • Model TW40-8: form 2F, Model TW40-9: form 3F
  • For highly corrosion-resistant coating
  • With integrated neck tube
  • Model TW40-9: fast-response design
Datasheet
User Manual

  • Ergonomic handling through the smooth-running, internally operating, precision spindle
  • Integrated oil reservoir
  • Removable star handle
  • Freely rotating test connections (i.e. measuring instruments can be aligned)
  • Precise setting of the test pressure through a fine adjustment valve (optional for model CPP1000-M)
Datasheet
User Manual

  • Total measurement uncertainty up to 0.025 % of reading
  • Upgradeable using CPS5800/CPM5800 to provide increased accuracy to 0.006 %
  • Direct replacement of original DH-Budenberg 580 series
  • Factory calibration included as standard, traceable to national standards, with UKAS calibration possible as an option
  • Masses manufactured from stainless steel, can be adjusted to local gravity
Datasheet
User Manual

  • No power supply needed for switching of electrical loads
  • Robust switch enclosure from aluminium alloy or stainless steel with identical dimensions, IP66, NEMA 4X
  • Setting ranges from 0.2 ... 1.2 to 200 ... 1,000 bar, vacuum ranges
  • Intrinsic safety Ex ia available
  • 1 set point, SPDT or DPDT, high switching power up to AC 250 V, 15 A
Datasheet
User Manual

  • Sealed, pressure retaining design
  • Density range from 340 kg/m³
  • Pressures up to 400 bar
  • Medium temperatures from -196 ... +450 °C
  • Versions for interface layer
Datasheet
User Manual

  • Hygienic design (dead space free transitions)
  • Residue-free and quick cleaning of the measuring point (piggable, suitable for SIP and CIP)
  • Materials and surface finish qualities in accordance with pharmaceutical industry directives and standards
  • High measuring accuracy with short response times
  • Explosion-protected versions



Datasheet
User Manual
User Manual
User Manual

  • No configuration necessary due to “plug-and-play”
  • Signal transmission per NAMUR
  • Differential pressure measuring ranges from 0 … 16 mbar
  • Easy-to-read analogue display with nominal sizes 100 and 160
  • Individual, non-linear characteristic curves (e. g. x2 or √x for flow measurement)
Datasheet
User Manual

  • Digital indicator with interchangeable pressure sensors (plug-and-play)
  • Measuring ranges from 0 ... 25 mbar to 0 ... 1,000 bar (0 ... 0.4 psi to 0 ... 14,500 psi)
  • Type of pressure: positive and negative overpressure, absolute pressure and differential pressure
  • Accuracy: 0.2 %, optional 0.1 % (incl. calibration certificate)
  • Software and complete service cases (incl. pumps) available
Datasheet
User Manual

  • Completely from stainless steel
  • Knife edge pointer for optimal accuracy of reading
  • Wear-resistant precision movement from stainless steel
  • Scale ranges from 0 … 0.6 to 0 … 1,600 bar [0 ... 10 psi to 0 ... 20,000 psi]
Datasheet
User Manual
User Manual

  • Up to 4 switch contacts per instrument
  • Also available with case filling for high dynamic pressure loads or vibrations
  • Instruments with inductive contacts for use in hazardous areas
  • Instruments with contacts for PLC applications
  • Instruments optionally available in safety version S3 per EN 837
Datasheet
User Manual
User Manual

  • Sensor ranges from -196 ... +600 °C [-320 ... +1.112 °F]
  • With integrated fabricated protection tube
  • Spring-loaded measuring insert (replaceable)
  • Explosion-protected versions are available for many approval types (see data sheet page 2)


Datasheet
User Manual
User Manual
User Manual
User Manual
User Manual

  • Ergonomic handling through the smooth-running, internally operating, precision spindle
  • Integrated oil reservoir
  • Removable star handle
  • Freely rotating test connections (i.e. measuring instruments can be aligned)
  • Integrated priming pump for large test volumes
Datenblatt
Bedienungsanleitung

  • Process- and system-specific solutions possible
  • Operating limits: - Operating temperature: T = -80 ... +200 °C - Operating pressure: P = Vacuum up to 80 bar - Limit density: ρ ≥400 kg/m3
  • Wide variety of different electrical connections, process connections and materials
  • Optionally with programmable and configurable head-mounted transmitter for 4 ... 20 mA field signals, HART®, PROFIBUS® PA and FOUNDATION™ Fieldbus
  • Explosion-protected versions (option)
Datasheet
Datasheet
User Manual
User Manual
User Manual

  • Mit Gehäusefüllung (Typ 263) bei hohen dynamischen Druckbelastungen und Vibrationen
  • Typen 262.30 und 263.30: Sicherheitsausführung mit bruchsicherer Trennwand (Solidfront) nach Anforderungen von EN 837-1 und ASME B40.100
  • Eignung für besonders aggressive Messstoffe, da sehr hohe Korrosionsbeständigkeit
  • EMICOgauge-Ausführung, zur Vermeidung flüchtiger Emissionen
  • Anzeigebereiche von 0 … 0,6 bis 0 … 1.000 bar [0 ... 10 bis 0 ... 15.000 psi]
 
Datenblatt
Bedienungsanleitung
Bedienungsanleitung

  • Temperature ranges from -269 ... +400 °C [-452 ... +752 °F]
  • Versions for pressure ranges from vacuum to 500 bar [7,252 psi]
  • Special versions: High pressure, interface measurement
  • Explosion-protected versions
  • Signal processing is made using a separate model OSA-SC switching amplifier
Datasheet

  • IIoT-capable with LoRaWAN® transmission
  • Battery-operated LoRa® radio transmission based on LPWAN technology
  • High transmission range for the measured values (up to 10 km) with long battery life (up to 10 years)
  • Exchange of the radio unit possible in ATEX zones
Datasheet
User Manual

  • Model OTMT84: PROFIBUS® PA profile 3.02
  • Model OTMT85: FOUNDATION™ Fieldbus H1
  • Explosion-protected version Ex ia (intrinsically safe/FISCO) and Ex ec available
Datasheet
User Manual
User Manual

  • Dual mV/V display
  • 2x digital input and 4x digital output
  • Integrated multiple signal outputs available
  • Serial interface, RS-232 or RS-485
  • Ingress protection IP65
Datasheet

  • Wear-free flow monitoring of liquid media using them calorimetric principle
  • Flexibly configurable switching and analogue outputs for flow and temperature
  • Easily parameterisable via 3-button operation or optionally via IO-Link 1.1
  • Exact adaptation to the conditions on-site
Datasheet
User Manual