Showing all 22 results

  • Impedance measurement possible at different frequencies and signal shapes.
  • DC voltage measurement:
  • ±2.45 VDC (Res. 0,00001V)
  • ±24.5 VDC (Res. 0,0001V)
  • ±100 VDC (Res. 0,001V)
  • Storage of 300000 readings
  • Up to 1000 battery definitions can be transferred from a database to the device.
  • RF-ID Battery identification with transponders.
  • USB – Interface.
  • 10 hours of continuous operation.
Datasheet

block voltages+24VDC (0,0001V res.) battery voltage (DC): up to 600VDC (0,001V res) univeral sensor interface+2,4VDC (0,00001V res.)

Datasheet

  • Easy to operate
  • Expandable up to 120 voltage inputs
  • Block voltage +/- 16,6 VDC
  • 600VDC CAT III (5000 VDC est voltage)
  • Parallel testing of battery systems possible
Datasheet

  • the perfect mobile test system for recurring battery tests. In interaction with an electronic load, the condition of a battery system (SOH) can be precisely determined during a capacity test.
  • Battery systems of up to 127 blocks can be tested. If desired, two batteries (with a reduced number of blocks) can be tested. The maximum block voltage is 15V.
  • The test system uses relays with an increased dielectric strength of 3000VDC. In addition, 4 parallel working measuring circuits for block voltage measurement are integrated, which are galvanically separated from each other (5000VDC)

  • test a single battery of up to 127 x 2V blocks
  • two batteries in parallel
  • max block voltage 15V.
Datasheet
User Manual

  • High power battery capacity test system
  • Discharging current up to 1300A with external loads (up to 9)
  • Graphical display showing test parameters, curves and results
  • Internal memory
  • Light and easy to carry, with handles and wheels
  • Shunt or clamp metering of an additional current
  • Suitable for all battery types
Datasheet

  • Quality checks in the field, e. g. on wine and wine must (°Brix, °KMW, Oechsle, Baumé)
  • Checks for wort and apparent extract in beer (°Plato)
  • Fermentation graph for each tank directly on the screen
  • One device replaces all glass hydrometers in the workplace
Datasheet
User Manual

  • Quality checks in the field, e. g. on wine and wine must (°Brix, °KMW, Oechsle, Baumé)
  • Checks for wort and apparent extract in beer (°Plato)
  • Fermentation graph for each tank directly on the screen
  • One device replaces all glass hydrometers in the workplace
Datasheet
User Manual

  • For measuring flammable chemicals in hazardous environments
  • The only intrinsically safe portable density meter on the market (Ex marking [Ex] II 2 G Ex ib IIB T4)
  • Leak-proof sealed housing to withstand rough conditions
  • Protection class IP54
Datasheet
User Manual

  • For measuring petroleum samples in hazardous environments
  • The only intrinsically safe portable density meter on the market (Ex marking [Ex] II 2 G Ex ib IIB T4)
  • Fully complies with the ASTM D7777 and IP 559 standards
  • Protection class IP54
Datasheet
User Manual

  • For measuring the specific gravity of sulfuric acid in lead-acid batteries in one second
  • Ideal for use in lead-acid battery production and the maintenance of uninterruptible power supply systems (UPS)
  • Protection class IP54
  • High chemical resistance for use in harsh environments
Datasheet
User Manual

  • 4-digit measurements in 20 seconds
  • Ultra-fast measurement mode maximizes throughput
  • Best-in-class filling control provides reliable results
  • 200+ conversion tables for quicker results
Datasheet
User Manual

  • 5-digit accuracy in 30 seconds
  • The industry-proven device for QC for a wide range of samples
  • Eight additional parameters and seven sample changers available
  • Five industry-specific user profiles
  • 30+ guided workflows support your measurements
Datasheet
User Manual

  • Up to 6-digit accuracy without drifts
  • Perfect for highly dense samples
  • Auto-correction for highly viscous samples
  • Ideal for high-end R&D applications, authorities, and standards organizations
Datasheet
User Manual

The new DMA 4200 M is a density meter for exceptional conditions. It measures the density at temperatures between -10 °C and 200 °C and elevated pressures up to 500 bar. The Pulsed Excitation Method used by DMA 4200 M delivers the most stable density results based on comprehensive knowledge of the oscillation characteristics. The new automatic bubble detection, FillingCheck™, makes the DMA 4200 M compliant with ASTM D4052 and ASTM D5002. Viscosity influence is eliminated by a fast new viscosity correction, ensuring density results with an accuracy of up to 0.0002 g/cm3. The new Temperfect™ feature of DMA 4200 M allows immediate density measurements at any temperature between 0 °C and 150 °C at ambient pressure. DMA 4200 M improves, accelerates, and simplifies density measurement of heavy petroleum samples.

Datasheet
User Manual

  • Measures the whole concentration range of sulfuric acid and oleum
  • Determines the concentration of two- and three-component solutions
  • Also ideal for phosphoric acid, formaldehyde, methanol, inks, and paints
  • Minimum sample volume increases safety for lab personnel
Datasheet
User Manual

Determines the alcohol and extract content in beer, wine, cider, spirits, liqueurs, and sake.

Brochure
User Manual

  • Intelligent modular battery monitoring
  • Flexible configurable for different applications
  • Continuous online measurement
  • Semiconductor switches (no relays)
  • Best performance /price ratio
 

  • No manual temperature correction required
  • You will receive the finished result: Values are displayed in% v / v (corrected to 20 ° C and 15 ° C for the Japanese market) or ° Proof (corrected to 60 ° F)
  • Accuracy of 0.2% v / v
  • The influence of viscosity on the density result is corrected automatically
  • Predefined calibration process with deionized water
  • New adjustment routine ensures alcohol measurements with an accuracy of up to 0.2% v / v, even at low measuring temperatures and low alcohol concentrations
Datasheet
User Manual

  • Accuracy of 0.1 %v/v
  • For on-site measurement at distilleries and craft distilleries
  • Sample identification via RFID tag
  • Store results and print or export them to a PC via Bluetooth® later on
Datasheet
User Manual

  • 3-digit digital density measurement from the market leader
  • Small is big: only 1 mL sample volume avoids wasting product
  • Big is bigger: 7” glove-friendly touchscreen for great usability
  • No manual calculations due to 60+ conversion tables
  • Ready for pasty, inhomogeneous, particle-containing samples
Datasheet
User Manual

  • The most advanced 4-digit density meter in this price segment
  • 100 % consistent results due to repeatability of 0.00005 g/cm3
  • Covers ASTM D4052, ASTM D5002, ISO 12185, USP <841>, Ph. Eur. 2.25, JP 17 2.56, ChP(Vol IV) 0601, and FDA CFR 21 Part 11
  • Splash-proof, instrument self-diagnosis, no ventilation-related corrosion
Datasheet
User Manual

Diese Website benutzt Cookies. Wenn du die Website weiter nutzt, gehen wir von deinem Einverständnis aus.